P065A- GENERATOR PERFORMANCE

For a complete wiring diagram Refer to Section 8W.



Possible Causes
GENERATOR BELT
GENERATOR BELT TENSIONER
GENERATOR B+ CIRCUIT OPEN


Always perform the Pre-Diagnostic Troubleshooting procedure before proceeding. (Refer to 9 - ENGINE - DIAGNOSIS AND TESTING)



Diagnostic Test

1. CHECK FOR OTHER DTC'S

Turn the ignition on.
With the scan tool, check the ECM for LIN Bus or System Voltage related DTC's.

Are there any LIN Bus or System Voltage related DTCs?

Yes


No

2. GENERATOR B+ CIRCUIT

Turn the ignition off.
Using a test light connected to ground, probe the B+ circuit at the generator.

Does the test tight illuminate brightly?

Continue


No

3. CHECK GENERATOR DRIVE BELT

Visually inspect the generator drive belt for glazing, cracks and other problems.
Inspect the generator drive belt and tensioner for proper tension.

Were any problems found?

Yes


No

4. TEST DRIVE THE VEHICLE

Turn the ignition on.
With the scan tool, erase DTC's.
Test drive the vehicle.
With the scan tool, read DTC's.

Does the scan tool display this DTC?

Yes


No