3.8L

1.
Apply sealant to sensor threads (new replacement sensors will have sealant already applied).
2.
Install coolant temperature sensor into thermostat housing. Tighten to 11 Nm (8 ft. lbs.) torque.
3.
Connect wire connector.
4.
Fill cooling system.
(Refer to 7 - COOLING - STANDARD PROCEDURE).