Top AC & Heating Experts for hvac condensate pump Kure Beach, NC. Dial +1 910-799-6611. 24 Hour Calls. Guaranteed Services – Low Prices.

What We Do?

Residential
HVAC Service

Are you looking for residential heating or cooling support services that are centered on complete home comfort solutions? The experts at O'Brien Service Company sell, install, as well as fix HVAC systems of all makes and models. Contact us today!

Commercial
HVAC Service

Commercial cooling and heating repairs are inevitable. At O'Brien Service Company, we deliver an extensive variety of heating as well as cooling solutions to meet all of your commercial HVAC installation, replacement, repair work, and maintenance requirements.

Emergency
HVAC Service

Emergencies may and do occur, and when they do, rest comfortably that our team will be there for you! O'Brien Service Company can supply emergency services at any time of the day or night. Don’t hesitate to get in touch with us the minute an emergency occurs!

24 Hour Service

We deliver HVAC services 24 hours a day, 7 days a week, 365 days a year. Among our countless service options guarantees that your comfort demands are fulfilled within your timespan and that even your most worrisome heating or air conditioner issues will be resolved today. Your time is valuable– and our team won’t keep you waiting!

25 YEARS EXPERIENCE

With over two decades of experience bringing our client’s total satisfaction, O'Brien Service Company is a top provider of HVAC services. Serving residential properties and businesses throughout , we complete regular maintenance, repairs and new installations customized to your needs and budget demands.

Testimonials

Contact Us

O’Brien Service Company

3308 Enterprise Dr, Wilmington, NC 28405, United States

Telephone

+1 910-799-6611

Hours

Mon-Fri, 8am – 5:30pm

More About Kure Beach, NC

Kure Beach (ˈkjʊəri KYUR-ee)[5] is a town in New Hanover County, North Carolina, about 15 miles south of Wilmington. It is part of the Wilmington Metropolitan Statistical Area. The population was 2,012 at the 2010 census. It is found on Pleasure Island directly south of the Wilmington Beach annex of Carolina Beach and just north of Fort Fisher.

A post office called Kure Beach has been in operation since 1942.[6] The town was named for a family of settlers.[7]

Space pressure can be either favorable or unfavorable with respect to outside the room. Favorable pressure happens when there is more air being supplied than exhausted, and is common to lower the seepage of outdoors pollutants. Natural ventilation is a crucial consider minimizing the spread of air-borne illnesses such as tuberculosis, the common cold, influenza and meningitis.

Natural ventilation needs little upkeep and is low-cost. A cooling system, or a standalone air conditioner, provides cooling and humidity control for all or part of a structure. Air conditioned buildings frequently have sealed windows, because open windows would work against the system planned to preserve consistent indoor air conditions.

The portion of return air comprised of fresh air can usually be controlled by changing the opening of this vent. Typical fresh air consumption has to do with 10%. [] Cooling and refrigeration are offered through the elimination of heat. Heat can be eliminated through radiation, convection, or conduction. Refrigeration conduction media such as water, air, ice, and chemicals are described as refrigerants.

It is important that the a/c horse power is adequate for the location being cooled. Underpowered air conditioning system will lead to power wastage and ineffective use. Adequate horse power is required for any ac system set up. The refrigeration cycle utilizes four necessary aspects to cool. The system refrigerant begins its cycle in a gaseous state.

From there it gets in a heat exchanger (in some cases called a condensing coil or condenser) where it loses energy (heat) to the outside, cools, and condenses into its liquid stage. An (also called metering gadget) controls the refrigerant liquid to flow at the correct rate. The liquid refrigerant is gone back to another heat exchanger where it is permitted to evaporate, thus the heat exchanger is often called an evaporating coil or evaporator.

While doing so, heat is absorbed from inside your home and transferred outdoors, resulting in cooling of the building. In variable climates, the system might include a reversing valve that changes from heating in winter season to cooling in summertime. By reversing the circulation of refrigerant, the heat pump refrigeration cycle is changed from cooling to heating or vice versa.

Free cooling systems can have very high efficiencies, and are sometimes combined with seasonal thermal energy storage so that the cold of winter season can be utilized for summertime a/c. Common storage mediums are deep aquifers or a natural underground rock mass accessed through a cluster of small-diameter, heat-exchanger-equipped boreholes.

The heatpump is added-in because the storage acts as a heat sink when the system is in cooling (rather than charging) mode, causing the temperature to gradually increase during the cooling season. Some systems include an “economizer mode”, which is sometimes called a “free-cooling mode”. When saving money, the control system will open (completely or partially) the outdoors air damper and close (completely or partly) the return air damper.

When the outside air is cooler than the demanded cool air, this will allow the need to be met without using the mechanical supply of cooling (usually cooled water or a direct expansion “DX” unit), thus conserving energy. The control system can compare the temperature level of the outside air vs.

In both cases, the outside air must be less energetic than the return air for the system to go into the economizer mode. Central, “all-air” air-conditioning systems (or package systems) with a combined outside condenser/evaporator system are typically set up in North American houses, workplaces, and public buildings, but are hard to retrofit (install in a building that was not developed to get it) since of the bulky duct required.

An option to packaged systems is the use of separate indoor and outside coils in split systems. Split systems are preferred and widely used around the world except in The United States and Canada. In The United States and Canada, divided systems are usually seen in property applications, however they are gaining popularity in little business buildings.

The benefits of ductless a/c systems consist of easy setup, no ductwork, greater zonal control, flexibility of control and quiet operation. [] In space conditioning, the duct losses can represent 30% of energy intake. Using minisplit can lead to energy cost savings in area conditioning as there are no losses associated with ducting.

Indoor systems with directional vents install onto walls, suspended from ceilings, or suit the ceiling. Other indoor systems mount inside the ceiling cavity, so that brief lengths of duct handle air from the indoor unit to vents or diffusers around the rooms. Split systems are more effective and the footprint is generally smaller than the bundle systems.