Top HVAC Pros for hvac maintenance Lyons, CO. Call +1 303-451-5057. 24 Hour Calls. Guaranteed Services – Low Prices.
What We Do?
Residential
HVAC Service
Are you searching for home heating or cooling services that are focused on total home comfort solutions? The professionals at Brothers Plumbing, Heating, and Electric sell, install, and fix HVAC units of all makes and models. Reach out to us today!
Commercial
HVAC Service
Commercial heating and cooling repairs are inevitable. At Brothers Plumbing, Heating, and Electric, we deliver a comprehensive variety of heating as well as cooling support services to meet all of your commercial HVAC installation, replacement, repair, and servicing demands.
Emergency
HVAC Service
Emergencies will and definitely do occur, when they do, rest assured that our team will be there for you! Brothers Plumbing, Heating, and Electric can easily provide emergency support at any moment of the day or night. Never hesitate to call us the moment an emergency occurs!


24 Hour Service
We offer HVAC services 24 hours a day, 7 days a week, 365 days a year. One of our many service options ensures that your comfort requirements are met within your time frame and also even your trickiest heating or air conditioner problems will be resolved today. Your time is precious– and our company will not keep you waiting!

25 YEARS EXPERIENCE
With over two decades of experience bringing our customer’s total satisfaction, Brothers Plumbing, Heating, and Electric is a leading provider of HVAC services. Serving homes and businesses throughout , we complete regular maintenance, repair work and new installations customized to your needs and budget guidelines.
Testimonials
Contact Us
Brothers Plumbing, Heating, and Electric
12249 Pennsylvania St, Thornton, CO 80241, United States
Telephone
+1 303-451-5057
Hours
Mon-Fri, 7am-10pm
Sat-Sun, 7am-8pm
We also provide hvac repair services in the following cities
- home ac Platteville, CO
- heat pump prices Platteville, CO
- central air conditioning unit Thornton, CO
- ac maintenance Brook Forest, CO
- ac system Conifer, CO
- heating and cooling companies Richlawn Hills, CO
- high efficiency furnace Platteville, CO
- heating companies Mead, CO
- hvac maintenance Conifer, CO
- high efficiency furnace Sedalia, CO
- new air conditioner Conifer, CO
- ac heater unit Caribou City, CO
- central air conditioning unit Richlawn Hills, CO
- new air conditioner Crestview, CO
- central air conditioning unit Longmont, CO
- home ac Thornton, CO
- hvac maintenance Crestview, CO
- ac maintenance Platteville, CO
- heating and cooling companies Perigo, CO
- ac maintenance Caribou City, CO
More About Lyons, CO
The Town of Lyons is a Statutory Town in Boulder County, Colorado, United States. The town population was 2033 at the 2010 United States Census,[9] up from 1585 at the 2000 United States Census. Lyons is located at the confluence of North St. Vrain Creek and South St. Vrain Creek, 20 miles (32 km) east of Rocky Mountain National Park. Due to its location at the intersection of State Highway 7 and U.S. Highway 36 which lead to Rocky Mountain National Park, it is sometimes referred to as “The Double Gateway to the Rockies”.[2]
Lyons is located in northern Boulder County at 40°13′26″N 105°16′8″W / 40.22389°N 105.26889°W / 40.22389; -105.26889 (40.223935, -105.269013).[10]
Room pressure can be either favorable or unfavorable with respect to outside the space. Positive pressure occurs when there is more air being supplied than exhausted, and prevails to reduce the seepage of outdoors impurities. Natural ventilation is a key consider lowering the spread of airborne diseases such as tuberculosis, the typical cold, influenza and meningitis.
Natural ventilation requires little upkeep and is low-cost. An air conditioning system, or a standalone air conditioner, offers cooling and humidity control for all or part of a building. Air conditioned buildings often have actually sealed windows, because open windows would work against the system planned to keep constant indoor air conditions.
The portion of return air comprised of fresh air can usually be manipulated by changing the opening of this vent. Common fresh air consumption has to do with 10%. [] Air conditioning and refrigeration are provided through the elimination of heat. Heat can be eliminated through radiation, convection, or conduction. Refrigeration conduction media such as water, air, ice, and chemicals are described as refrigerants.

It is vital that the cooling horse power is adequate for the location being cooled. Underpowered air conditioning system will lead to power wastage and ineffective usage. Appropriate horsepower is needed for any air conditioner installed. The refrigeration cycle utilizes 4 important aspects to cool. The system refrigerant begins its cycle in a gaseous state.
From there it gets in a heat exchanger (sometimes called a condensing coil or condenser) where it loses energy (heat) to the outside, cools, and condenses into its liquid stage. An (also called metering device) controls the refrigerant liquid to stream at the correct rate. The liquid refrigerant is gone back to another heat exchanger where it is enabled to vaporize, for this reason the heat exchanger is often called an evaporating coil or evaporator.
While doing so, heat is absorbed from inside your home and transferred outdoors, leading to cooling of the structure. In variable environments, the system may consist of a reversing valve that changes from heating in winter season to cooling in summer. By reversing the circulation of refrigerant, the heat pump refrigeration cycle is changed from cooling to heating or vice versa.
Free cooling systems can have very high performances, and are sometimes combined with seasonal thermal energy storage so that the cold of winter can be used for summer air conditioning. Typical storage mediums are deep aquifers or a natural underground rock mass accessed through a cluster of small-diameter, heat-exchanger-equipped boreholes.
The heat pump is added-in because the storage acts as a heat sink when the system remains in cooling (instead of charging) mode, causing the temperature level to slowly increase during the cooling season. Some systems include an “economizer mode”, which is sometimes called a “free-cooling mode”. When economizing, the control system will open (completely or partially) the outside air damper and close (completely or partly) the return air damper.
When the outside air is cooler than the required cool air, this will permit the demand to be met without using the mechanical supply of cooling (typically cooled water or a direct growth “DX” system), thus conserving energy. The control system can compare the temperature level of the outside air vs.
In both cases, the outside air should be less energetic than the return air for the system to get in the economizer mode. Central, “all-air” air-conditioning systems (or bundle systems) with a combined outdoor condenser/evaporator unit are frequently installed in North American homes, offices, and public structures, however are challenging to retrofit (install in a structure that was not developed to receive it) since of the large duct required.

An alternative to packaged systems is making use of separate indoor and outdoor coils in split systems. Split systems are chosen and widely utilized worldwide other than in North America. In The United States and Canada, divided systems are most frequently seen in property applications, but they are gaining appeal in small business buildings.
The advantages of ductless cooling systems consist of simple installation, no ductwork, greater zonal control, flexibility of control and quiet operation. [] In area conditioning, the duct losses can represent 30% of energy usage. Using minisplit can lead to energy savings in space conditioning as there are no losses related to ducting.
Indoor units with directional vents install onto walls, suspended from ceilings, or suit the ceiling. Other indoor units mount inside the ceiling cavity, so that brief lengths of duct manage air from the indoor system to vents or diffusers around the spaces. Split systems are more efficient and the footprint is generally smaller sized than the package systems.
