Find Us At

963 Folsom Ave
Salt Lake City, UT 84104

Call Us At

+1 801-446-6642

Business Hours

Open 24 hours

Best Heating & Cooling Experts for commercial hvac stallation South Jordan, UT. Phone +1 801-446-6642. 24 Hour Calls. Guaranteed Services – Low Prices.

What We Do?

Residential
HVAC Service

Are you looking for home heating or cooling support services that are focused on total home comfort solutions? The specialists at Whipple Service Champions sell, install, as well as repair HVAC systems of all makes and models. Call us today!

Commercial
HVAC Service

Commercial heating and cooling repairs are unavoidable. At Whipple Service Champions, we deliver a comprehensive variety of heating and cooling support services to meet all of your commercial HVAC installation, replacement, repair work, and servicing demands.

Emergency
HVAC Service

Emergencies can and definitely do occur, when they do, rest assured that our experts will be there for you! Whipple Service Champions can easily provide emergency services at any time of the day or night. Don’t hesitate to call us the minute an emergency happens!

24 Hour Service

We deliver HVAC services 24 hours a day, 7 days a week, 365 days a year. One of our many service options ensures that your comfort needs are fulfilled within your timespan and that even your most worrisome heating or air conditioner issues will be fixed today. Your time is precious– and our company won’t keep you waiting!

25 YEARS EXPERIENCE

With over two decades of experience bringing our customer’s total satisfaction, Whipple Service Champions is a leading provider of HVAC services. Serving residential properties and businesses in , we complete regular servicing, repairs and also new installations customized to your needs and budget requirements.

Testimonials

Contact Us

Whipple Service Champions

963 Folsom Ave, Salt Lake City, UT 84104, United States

Telephone

+1 801-446-6642

Hours

Open 24 hours

More About South Jordan, UT

South Jordan is a city in south central Salt Lake County, Utah, 18 miles (29 km) south of Salt Lake City. Part of the Salt Lake City metropolitan area, the city lies in the Salt Lake Valley along the banks of the Jordan River between the 9,000-foot (2,700 m) Oquirrh Mountains and the 12,000-foot (3,700 m) Wasatch Mountains. The city has 3.5 miles (5.6 km) of the Jordan River Parkway that contains fishing ponds, trails, parks, and natural habitats. The Salt Lake County fair grounds and equestrian park, 67-acre (27 ha) Oquirrh Lake, and 27 parks are located inside the city. as of 2018, there were 74,149 people in South Jordan.[6]

Founded in 1859 by Mormon settlers and historically an agrarian town, South Jordan has become a rapidly growing bedroom community of Salt Lake City. Kennecott Land, a land development company, has recently begun construction on the master-planned Daybreak Community for the entire western half of South Jordan, potentially doubling South Jordan’s population. South Jordan is the first city in the world with two temples of The Church of Jesus Christ of Latter-day Saints, Jordan River Utah Temple and Oquirrh Mountain Utah Temple. The city has two TRAX light rail stops, as well as one commuter rail stop on the FrontRunner. South Jordan is also a growing tech hub with headquarters of companies like IT software company Ivanti.

Space pressure can be either favorable or negative with respect to outside the space. Positive pressure occurs when there is more air being supplied than tired, and is typical to lower the infiltration of outdoors pollutants. Natural ventilation is a crucial element in decreasing the spread of air-borne diseases such as tuberculosis, the acute rhinitis, influenza and meningitis.

Natural ventilation requires little upkeep and is affordable. A cooling system, or a standalone air conditioner, provides cooling and humidity control for all or part of a structure. Air conditioned structures often have actually sealed windows, since open windows would work against the system planned to keep consistent indoor air conditions.

The portion of return air made up of fresh air can usually be manipulated by adjusting the opening of this vent. Normal fresh air intake has to do with 10%. [] A/c and refrigeration are provided through the removal of heat. Heat can be removed through radiation, convection, or conduction. Refrigeration conduction media such as water, air, ice, and chemicals are described as refrigerants.

It is crucial that the cooling horse power suffices for the area being cooled. Underpowered a/c system will lead to power wastage and ineffective use. Sufficient horsepower is required for any a/c unit installed. The refrigeration cycle uses 4 necessary elements to cool. The system refrigerant starts its cycle in a gaseous state.

From there it enters a heat exchanger (sometimes called a condensing coil or condenser) where it loses energy (heat) to the outdoors, cools, and condenses into its liquid stage. An (also called metering gadget) controls the refrigerant liquid to stream at the correct rate. The liquid refrigerant is gone back to another heat exchanger where it is permitted to vaporize, for this reason the heat exchanger is often called an evaporating coil or evaporator.

While doing so, heat is taken in from indoors and moved outdoors, resulting in cooling of the building. In variable environments, the system may consist of a reversing valve that switches from heating in winter to cooling in summer. By reversing the flow of refrigerant, the heatpump refrigeration cycle is altered from cooling to heating or vice versa.

Free cooling systems can have very high performances, and are in some cases combined with seasonal thermal energy storage so that the cold of winter season can be used for summer cooling. Typical storage mediums are deep aquifers or a natural underground rock mass accessed through a cluster of small-diameter, heat-exchanger-equipped boreholes.

The heat pump is added-in since the storage functions as a heat sink when the system remains in cooling (as opposed to charging) mode, triggering the temperature to gradually increase during the cooling season. Some systems consist of an “economizer mode”, which is sometimes called a “free-cooling mode”. When saving money, the control system will open (fully or partly) the outdoors air damper and close (fully or partly) the return air damper.

When the outdoors air is cooler than the demanded cool air, this will enable the need to be fulfilled without using the mechanical supply of cooling (usually cooled water or a direct expansion “DX” system), therefore conserving energy. The control system can compare the temperature level of the outside air vs.

In both cases, the outdoors air should be less energetic than the return air for the system to go into the economizer mode. Central, “all-air” air-conditioning systems (or bundle systems) with a combined outdoor condenser/evaporator system are frequently set up in North American houses, offices, and public buildings, however are hard to retrofit (set up in a building that was not developed to receive it) because of the large air ducts required.

An alternative to packaged systems is making use of separate indoor and outdoor coils in split systems. Split systems are chosen and widely used worldwide other than in North America. In The United States and Canada, split systems are usually seen in residential applications, but they are gaining appeal in little business buildings.

The advantages of ductless cooling systems include simple installation, no ductwork, greater zonal control, versatility of control and quiet operation. [] In area conditioning, the duct losses can represent 30% of energy usage. The use of minisplit can result in energy savings in area conditioning as there are no losses related to ducting.

Indoor units with directional vents install onto walls, suspended from ceilings, or fit into the ceiling. Other indoor units mount inside the ceiling cavity, so that short lengths of duct deal with air from the indoor system to vents or diffusers around the rooms. Split systems are more efficient and the footprint is generally smaller sized than the package systems.

Call Now

Call Now