Find Us At

1019 Knowles Rd
Phenix City, AL 36869

Call Us At

+1 334-298-1278

Business Hours

Mon-Sun, 8am - 9pm

Best HVAC Experts for hvac direct Hurtsboro, AL. Phone +1 334-298-1278. 24 Hour Calls. Guaranteed Services – Low Prices.

What We Do?

Residential
HVAC Service

Are you looking for residential heating or cooling services that are focused on home comfort remedies? The professionals at Riley Heating & Air Conditioning sell, install, and repair HVAC units of all makes and models. Reach out to us today!

Commercial
HVAC Service

Commercial heating and cooling maintenance and repairs are unavoidable. At Riley Heating & Air Conditioning, we supply a comprehensive variety of heating and cooling services to meet each of your commercial HVAC installation, replacement, repair work, and servicing requirements.

Emergency
HVAC Service

Emergencies may and definitely do occur, when they do, rest assured that our experts will be there for you! Riley Heating & Air Conditioning can easily supply emergency services at any moment of the day or night. Don’t hesitate to contact us the second an emergency occurs!

24 Hour Service

We offer HVAC services 24 hours a day, 7 days a week, 365 days a year. One of our various service options ensures that your comfort demands are fulfilled within your timespan and also even your most worrisome heating or air conditioner problems will be solved today. Your time is precious– and our experts won’t keep you waiting!

25 YEARS EXPERIENCE

With over two decades of experience bringing our customer’s total satisfaction, Riley Heating & Air Conditioning is a premier provider of HVAC services. Serving homes and businesses within , we complete routine servicing, repairs as well as new installations modified to your needs and budget demands.

Testimonials

Contact Us

Riley Heating & Air Conditioning

1019 Knowles Rd, Phenix City, AL 36869, United States

Telephone

+1 334-298-1278

Hours

Mon-Sun, 8am – 9pm

More About Hurtsboro, AL

Hurtsboro is a town in Russell County, Alabama, United States. At the 2010 census the population was 553, down from 592 in 2000. It was founded in 1857 as Hurtsville and named for Joel Hurt, Sr. (whose son, Joel Hurt, was an important developer of Atlanta, Georgia). A railroad spur from Columbus, Georgia was completed the next year. It was incorporated in 1872 and in 1883 the town name was changed to Hurtsboro.

Room pressure can be either positive or unfavorable with respect to outside the space. Favorable pressure takes place when there is more air being supplied than exhausted, and is common to minimize the seepage of outside impurities. Natural ventilation is a crucial factor in minimizing the spread of air-borne health problems such as tuberculosis, the typical cold, influenza and meningitis.

Natural ventilation requires little maintenance and is economical. An a/c system, or a standalone a/c unit, supplies cooling and humidity control for all or part of a structure. Air conditioned buildings often have sealed windows, since open windows would work against the system planned to maintain continuous indoor air conditions.

The percentage of return air comprised of fresh air can normally be manipulated by changing the opening of this vent. Common fresh air consumption has to do with 10%. [] A/c and refrigeration are offered through the removal of heat. Heat can be gotten rid of through radiation, convection, or conduction. Refrigeration conduction media such as water, air, ice, and chemicals are referred to as refrigerants.

It is important that the a/c horsepower suffices for the area being cooled. Underpowered a/c system will result in power waste and ineffective use. Appropriate horse power is required for any a/c set up. The refrigeration cycle utilizes four essential aspects to cool. The system refrigerant begins its cycle in a gaseous state.

From there it gets in a heat exchanger (often called a condensing coil or condenser) where it loses energy (heat) to the outdoors, cools, and condenses into its liquid phase. An (also called metering device) regulates the refrigerant liquid to stream at the correct rate. The liquid refrigerant is returned to another heat exchanger where it is allowed to evaporate, hence the heat exchanger is frequently called an evaporating coil or evaporator.

In the procedure, heat is absorbed from inside your home and transferred outdoors, resulting in cooling of the building. In variable climates, the system might consist of a reversing valve that switches from heating in winter season to cooling in summer. By reversing the circulation of refrigerant, the heatpump refrigeration cycle is changed from cooling to heating or vice versa.

Free cooling systems can have very high efficiencies, and are sometimes combined with seasonal thermal energy storage so that the cold of winter can be utilized for summertime a/c. Common storage mediums are deep aquifers or a natural underground rock mass accessed by means of a cluster of small-diameter, heat-exchanger-equipped boreholes.

The heatpump is added-in due to the fact that the storage serves as a heat sink when the system is in cooling (instead of charging) mode, triggering the temperature to gradually increase throughout the cooling season. Some systems include an “economizer mode”, which is sometimes called a “free-cooling mode”. When economizing, the control system will open (completely or partly) the outside air damper and close (completely or partially) the return air damper.

When the outside air is cooler than the demanded cool air, this will enable the demand to be satisfied without utilizing the mechanical supply of cooling (usually chilled water or a direct expansion “DX” system), therefore saving energy. The control system can compare the temperature level of the outdoors air vs.

In both cases, the outside air needs to be less energetic than the return air for the system to enter the economizer mode. Central, “all-air” air-conditioning systems (or plan systems) with a combined outside condenser/evaporator system are often installed in North American residences, workplaces, and public buildings, however are difficult to retrofit (set up in a building that was not designed to get it) because of the bulky air ducts needed.

An alternative to packaged systems is the usage of separate indoor and outdoor coils in split systems. Split systems are chosen and commonly used worldwide except in The United States and Canada. In The United States and Canada, split systems are most frequently seen in domestic applications, however they are getting popularity in small business structures.

The benefits of ductless cooling systems consist of easy installation, no ductwork, greater zonal control, flexibility of control and peaceful operation. [] In space conditioning, the duct losses can represent 30% of energy usage. Making use of minisplit can result in energy cost savings in space conditioning as there are no losses associated with ducting.

Indoor systems with directional vents install onto walls, suspended from ceilings, or suit the ceiling. Other indoor units install inside the ceiling cavity, so that brief lengths of duct deal with air from the indoor unit to vents or diffusers around the spaces. Split systems are more effective and the footprint is typically smaller sized than the plan systems.

Call Now

Call Now