Best AC & Heating Pros for hvac compressor Valley, AL. Call +1 334-298-1278. 24 Hour Calls. Guaranteed Services – Low Prices.
What We Do?
Residential
HVAC Service
Are you looking for residential heating and cooling support services that are centered on home comfort remedies? The specialists at Riley Heating & Air Conditioning sell, install, and repair HVAC systems of all makes and models. Call us today!
Commercial
HVAC Service
Commercial cooling and heating repairs are unavoidable. At Riley Heating & Air Conditioning, we provide a comprehensive array of heating and cooling solutions to meet every one of your commercial HVAC installation, replacement, repair work, and servicing needs.
Emergency
HVAC Service
Emergencies may and definitely do develop, and when they do, rest comfortably that our team will be there for you! Riley Heating & Air Conditioning is able to provide emergency services at any moment of the day or night. Don’t hesitate to call us the minute an emergency happens!


24 Hour Service
We offer HVAC services 24 hours a day, 7 days a week, 365 days a year. One of our various service options guarantees that your comfort needs are satisfied within your timespan and that even your most worrisome heating or air conditioner issues will be handled today. Your time is precious– and our company won’t keep you waiting!

25 YEARS EXPERIENCE
With over two decades of experience bringing our customer’s total satisfaction, Riley Heating & Air Conditioning is a top provider of HVAC services. Serving homes and businesses in , we perform routine servicing, repair work and also new installations tailored to your needs and budget requirements.
Testimonials
Contact Us
Riley Heating & Air Conditioning
1019 Knowles Rd, Phenix City, AL 36869, United States
Telephone
+1 334-298-1278
Hours
Mon-Sun, 8am – 9pm
We also provide hvac repair services in the following cities
- hvac contractors Cataula, AL
- hvac condensate pump Pittsview, AL
- high velocity hvac Hurtsboro, AL
- hvac emergency service near me Columbus, AL
- hvac air filters Ellerslie, AL
- hvac emergency Fort Mitchell, AL
- commercial hvac service technician Lumpkin, AL
- emergency hvac near me Fort Mitchell, AL
- hvac air filters Fort Mitchell, AL
- hvac air filters Pittsview, AL
- high velocity hvac Lumpkin, AL
- hvac air purifier Fort Benning, AL
- hvac contractors Smiths Station, AL
- hvac compressor Pittsview, AL
- emergency hvac services near me Fort Mitchell, AL
- hvac courses Lumpkin, AL
- hvac emergency service Smiths Station, AL
- heat pump hvac Ellerslie, AL
- hvac emergency Valley, AL
- emergency hvac near me Columbus, AL
More About Valley, AL
Valley is a city in Chambers County, Alabama, United States. Valley was incorporated in 1980 combining the four textile mill villages of Fairfax, Langdale, River View, and Shawmut.[3] As of the 2010 census it had a population of 9,524.[4] The city lies on the western bank of the Chattahoochee River, the state border between Alabama and Georgia. Valley is a pilot city for the Alabama Communities of Excellence[5] program, a non-profit that partners with governments, businesses, and universities to prepare participating communities for a more vibrant future.[6] It is the principal city of and is included in the Valley, Alabama Micropolitan Statistical Area, which is included in the Greater Columbus Combined Statistical Area.[7]
Valley is located in southeastern Chambers County at 32°48’40.993″ North, 85°10’40.577″ West (32.811387, -85.177938).[8] According to the U.S. Census Bureau, the city has a total area of 11.0 square miles (28.6 km2), all land.[4]
Room pressure can be either positive or negative with respect to outside the space. Positive pressure happens when there is more air being supplied than tired, and is typical to minimize the seepage of outdoors impurities. Natural ventilation is an essential consider decreasing the spread of airborne illnesses such as tuberculosis, the common cold, influenza and meningitis.
Natural ventilation needs little upkeep and is low-cost. An air conditioning system, or a standalone ac system, provides cooling and humidity control for all or part of a building. Air conditioned buildings typically have sealed windows, due to the fact that open windows would work versus the system intended to keep consistent indoor air conditions.
The percentage of return air comprised of fresh air can typically be manipulated by changing the opening of this vent. Normal fresh air intake is about 10%. [] Cooling and refrigeration are provided through the removal of heat. Heat can be removed through radiation, convection, or conduction. Refrigeration conduction media such as water, air, ice, and chemicals are described as refrigerants.

It is imperative that the cooling horse power suffices for the area being cooled. Underpowered cooling system will cause power waste and ineffective use. Sufficient horsepower is required for any air conditioner set up. The refrigeration cycle uses 4 essential elements to cool. The system refrigerant starts its cycle in a gaseous state.
From there it goes into a heat exchanger (sometimes called a condensing coil or condenser) where it loses energy (heat) to the outdoors, cools, and condenses into its liquid phase. An (likewise called metering gadget) regulates the refrigerant liquid to flow at the correct rate. The liquid refrigerant is returned to another heat exchanger where it is permitted to vaporize, for this reason the heat exchanger is frequently called an evaporating coil or evaporator.
In the process, heat is soaked up from indoors and transferred outdoors, leading to cooling of the building. In variable environments, the system might include a reversing valve that switches from heating in winter to cooling in summer. By reversing the flow of refrigerant, the heat pump refrigeration cycle is changed from cooling to heating or vice versa.
Free cooling systems can have really high efficiencies, and are sometimes combined with seasonal thermal energy storage so that the cold of winter season can be utilized for summer season air conditioning. Common storage mediums are deep aquifers or a natural underground rock mass accessed by means of a cluster of small-diameter, heat-exchanger-equipped boreholes.
The heat pump is added-in due to the fact that the storage serves as a heat sink when the system remains in cooling (rather than charging) mode, triggering the temperature level to slowly increase throughout the cooling season. Some systems consist of an “economizer mode”, which is often called a “free-cooling mode”. When saving money, the control system will open (completely or partly) the outside air damper and close (fully or partially) the return air damper.
When the outdoors air is cooler than the required cool air, this will enable the demand to be met without using the mechanical supply of cooling (generally cooled water or a direct growth “DX” unit), therefore conserving energy. The control system can compare the temperature level of the outdoors air vs.
In both cases, the outdoors air must be less energetic than the return air for the system to go into the economizer mode. Central, “all-air” air-conditioning systems (or bundle systems) with a combined outdoor condenser/evaporator system are frequently installed in North American homes, workplaces, and public buildings, however are challenging to retrofit (install in a building that was not developed to get it) due to the fact that of the large air ducts required.

An alternative to packaged systems is making use of different indoor and outdoor coils in split systems. Split systems are chosen and extensively used around the world except in The United States and Canada. In North America, divided systems are usually seen in domestic applications, but they are getting appeal in small business buildings.
The advantages of ductless a/c systems include simple setup, no ductwork, higher zonal control, flexibility of control and quiet operation. [] In area conditioning, the duct losses can represent 30% of energy usage. Using minisplit can lead to energy savings in space conditioning as there are no losses connected with ducting.
Indoor units with directional vents mount onto walls, suspended from ceilings, or suit the ceiling. Other indoor units install inside the ceiling cavity, so that brief lengths of duct manage air from the indoor system to vents or diffusers around the spaces. Split systems are more effective and the footprint is typically smaller than the package systems.