Find Us At

3909 196th St SW
Lynnwood, WA 98036

Call Us At

+1 800-398-4663

Business Hours

Mon-Fri : 8am-5pm Sat : 9am-1pm

Top AC & Heating Experts for heat pump prices Kenmore, WA. Call +1 800-398-4663. 24 Hour Calls. Guaranteed Services – Low Prices.

What We Do?

Residential
HVAC Service

Are you looking for residential heating or cooling support services that are centered on home comfort solutions? The specialists at Washington Energy Services sell, install, as well as fix HVAC systems of all makes and models. Contact us today!

Commercial
HVAC Service

Commercial heating and cooling repairs are unavoidable. At Washington Energy Services, we supply an extensive array of heating and cooling services to meet every one of your commercial HVAC installation, replacement, repair, and servicing needs.

Emergency
HVAC Service

Emergencies will and definitely do occur, and when they do, rest assured that our experts will be there for you! Washington Energy Services is able to deliver emergency assistance at any time of the day or night. Don’t hesitate to contact us the minute an emergency happens!

24 Hour Service

We deliver HVAC services 24 hours a day, 7 days a week, 365 days a year. One of our countless service options guarantees that your comfort demands are met within your time frame and also even your most worrisome heating and air conditioner problems will be solved today. Your time is valuable– and our company will never keep you waiting!

25 YEARS EXPERIENCE

With over two decades of experience bringing our customer’s complete satisfaction, Washington Energy Services is a premier provider of HVAC services. Serving homes and businesses throughout , we perform routine maintenance, repairs and also new installations tailored to your needs and budget demands.

Testimonials

Contact Us

Washington Energy Services

3909 196th St SW, Lynnwood, WA 98036, United States

Telephone

1 800-398-4663

Hours

Mon-Fri : 8am-5pm Sat : 9am-1pm

More About Kenmore, WA

Kenmore is a city in King County, Washington, United States, along the northernmost shore of Lake Washington. It is a suburban bedroom community that is located at the mouth of the Sammamish River, approximately 12 miles (19 km) northeast of Seattle and 2 miles (3.2 km) west of Bothell. The city’s population was 20,460 at the 2010 census. Kenmore is also home to the Kenmore Air Harbor, the largest seaplane-only passenger facility of its kind in the United States.[5]

The city is connected to nearby areas by State Route 522 and the Burke-Gilman Trail, which both run east–west along the lakeshore. The city limits stretch north to the Snohomish County line and south to a border with Kirkland south of Saint Edward State Park and Bastyr University. Kenmore’s official city flower is the dahlia, the official city bird is the great blue heron, and the official city evergreen is the rhododendron.

Room pressure can be either favorable or negative with regard to outside the room. Positive pressure takes place when there is more air being provided than exhausted, and prevails to lower the infiltration of outside impurities. Natural ventilation is a crucial consider lowering the spread of airborne diseases such as tuberculosis, the acute rhinitis, influenza and meningitis.

Natural ventilation needs little maintenance and is low-cost. A cooling system, or a standalone air conditioner, supplies cooling and humidity control for all or part of a building. Air conditioned structures frequently have actually sealed windows, because open windows would work against the system planned to preserve continuous indoor air conditions.

The portion of return air comprised of fresh air can normally be manipulated by adjusting the opening of this vent. Typical fresh air intake has to do with 10%. [] Air conditioning and refrigeration are provided through the elimination of heat. Heat can be gotten rid of through radiation, convection, or conduction. Refrigeration conduction media such as water, air, ice, and chemicals are referred to as refrigerants.

It is vital that the air conditioning horsepower suffices for the area being cooled. Underpowered a/c system will result in power waste and inefficient usage. Sufficient horse power is needed for any air conditioner installed. The refrigeration cycle utilizes four necessary components to cool. The system refrigerant begins its cycle in a gaseous state.

From there it goes into a heat exchanger (in some cases called a condensing coil or condenser) where it loses energy (heat) to the outdoors, cools, and condenses into its liquid stage. An (likewise called metering device) regulates the refrigerant liquid to flow at the proper rate. The liquid refrigerant is gone back to another heat exchanger where it is allowed to vaporize, hence the heat exchanger is frequently called an evaporating coil or evaporator.

At the same time, heat is soaked up from indoors and moved outdoors, resulting in cooling of the building. In variable climates, the system might include a reversing valve that switches from heating in winter season to cooling in summertime. By reversing the flow of refrigerant, the heat pump refrigeration cycle is changed from cooling to heating or vice versa.

Free cooling systems can have really high performances, and are sometimes integrated with seasonal thermal energy storage so that the cold of winter can be used for summertime a/c. Typical storage mediums are deep aquifers or a natural underground rock mass accessed through a cluster of small-diameter, heat-exchanger-equipped boreholes.

The heatpump is added-in because the storage functions as a heat sink when the system remains in cooling (rather than charging) mode, causing the temperature level to gradually increase throughout the cooling season. Some systems include an “economizer mode”, which is sometimes called a “free-cooling mode”. When economizing, the control system will open (fully or partially) the outdoors air damper and close (totally or partly) the return air damper.

When the outdoors air is cooler than the demanded cool air, this will permit the demand to be met without using the mechanical supply of cooling (generally chilled water or a direct growth “DX” unit), hence saving energy. The control system can compare the temperature of the outside air vs.

In both cases, the outside air must be less energetic than the return air for the system to go into the economizer mode. Central, “all-air” air-conditioning systems (or plan systems) with a combined outside condenser/evaporator unit are typically installed in North American homes, offices, and public structures, however are hard to retrofit (set up in a structure that was not designed to get it) because of the bulky duct needed.

An alternative to packaged systems is the use of separate indoor and outside coils in split systems. Split systems are chosen and commonly used around the world other than in The United States and Canada. In The United States and Canada, split systems are frequently seen in domestic applications, but they are gaining appeal in little business structures.

The benefits of ductless air conditioning systems include simple setup, no ductwork, higher zonal control, flexibility of control and peaceful operation. [] In area conditioning, the duct losses can represent 30% of energy consumption. Using minisplit can lead to energy savings in space conditioning as there are no losses related to ducting.

Indoor units with directional vents mount onto walls, suspended from ceilings, or suit the ceiling. Other indoor units mount inside the ceiling cavity, so that brief lengths of duct manage air from the indoor unit to vents or diffusers around the spaces. Split systems are more effective and the footprint is normally smaller sized than the plan systems.

Call Now

Call Now