Find Us At

3909 196th St SW
Lynnwood, WA 98036

Call Us At

+1 800-398-4663

Business Hours

Mon-Fri : 8am-5pm Sat : 9am-1pm

Best AC & Heating Experts for air conditioner maintenance Bothell, WA. Dial +1 800-398-4663. 24 Hour Calls. Guaranteed Services – Low Prices.

What We Do?

Residential
HVAC Service

Are you looking for residential heating or cooling services that are centered on complete home comfort solutions? The experts at Washington Energy Services sell, install, and also fix HVAC systems of all makes and models. Call us today!

Commercial
HVAC Service

Commercial heating and cooling repairs are inevitable. At Washington Energy Services, we supply an extensive array of heating and cooling support services to meet all of your commercial HVAC installation, replacement, repair work, and maintenance requirements.

Emergency
HVAC Service

Emergencies can and do occur, when they do, rest comfortably that we will will be there for you! Washington Energy Services can provide emergency support at any time of the day or night. Never hesitate to get in touch with us the minute an emergency happens!

24 Hour Service

We provide HVAC services 24 hours a day, 7 days a week, 365 days a year. Among our many service options ensures that your comfort requirements are satisfied within your timespan and also even your most worrisome heating and air conditioner concerns will be handled today. Your time is valuable– and our company will not keep you waiting!

25 YEARS EXPERIENCE

With over two decades of experience bringing our customer’s total satisfaction, Washington Energy Services is a top provider of HVAC services. Serving residential properties and businesses throughout , we complete routine servicing, repair work and also new installations tailored to your needs and budget requirements.

Testimonials

Contact Us

Washington Energy Services

3909 196th St SW, Lynnwood, WA 98036, United States

Telephone

1 800-398-4663

Hours

Mon-Fri : 8am-5pm Sat : 9am-1pm

More About Bothell, WA

Bothell (/ˈbɒθəl/) is a city in King and Snohomish counties in the U.S. state of Washington. It is part of the Seattle metropolitan area. As of the 2010 census it had a population of 33,505,[2] and in 2019 the estimated population was 47,415.[3]

Space pressure can be either favorable or unfavorable with regard to outside the room. Positive pressure happens when there is more air being supplied than exhausted, and is typical to lower the seepage of outside impurities. Natural ventilation is a crucial factor in reducing the spread of air-borne health problems such as tuberculosis, the typical cold, influenza and meningitis.

Natural ventilation needs little upkeep and is affordable. A cooling system, or a standalone air conditioning system, supplies cooling and humidity control for all or part of a structure. Air conditioned structures often have sealed windows, due to the fact that open windows would work against the system meant to keep consistent indoor air conditions.

The percentage of return air comprised of fresh air can generally be manipulated by changing the opening of this vent. Normal fresh air consumption has to do with 10%. [] Cooling and refrigeration are offered through the elimination of heat. Heat can be gotten rid of through radiation, convection, or conduction. Refrigeration conduction media such as water, air, ice, and chemicals are described as refrigerants.

It is essential that the cooling horsepower is enough for the location being cooled. Underpowered a/c system will result in power wastage and ineffective usage. Appropriate horsepower is needed for any a/c unit set up. The refrigeration cycle utilizes 4 essential elements to cool. The system refrigerant begins its cycle in a gaseous state.

From there it enters a heat exchanger (sometimes called a condensing coil or condenser) where it loses energy (heat) to the outside, cools, and condenses into its liquid phase. An (also called metering gadget) controls the refrigerant liquid to flow at the proper rate. The liquid refrigerant is gone back to another heat exchanger where it is enabled to vaporize, thus the heat exchanger is frequently called an evaporating coil or evaporator.

In the process, heat is soaked up from inside your home and moved outdoors, resulting in cooling of the structure. In variable environments, the system may consist of a reversing valve that switches from heating in winter season to cooling in summertime. By reversing the circulation of refrigerant, the heat pump refrigeration cycle is changed from cooling to heating or vice versa.

Free cooling systems can have really high efficiencies, and are sometimes combined with seasonal thermal energy storage so that the cold of winter season can be used for summer a/c. Common storage mediums are deep aquifers or a natural underground rock mass accessed by means of a cluster of small-diameter, heat-exchanger-equipped boreholes.

The heat pump is added-in because the storage acts as a heat sink when the system is in cooling (instead of charging) mode, causing the temperature level to gradually increase during the cooling season. Some systems consist of an “economizer mode”, which is in some cases called a “free-cooling mode”. When economizing, the control system will open (completely or partially) the outside air damper and close (fully or partly) the return air damper.

When the outdoors air is cooler than the demanded cool air, this will enable the need to be satisfied without utilizing the mechanical supply of cooling (normally cooled water or a direct expansion “DX” system), hence saving energy. The control system can compare the temperature of the outdoors air vs.

In both cases, the outside air needs to be less energetic than the return air for the system to get in the economizer mode. Central, “all-air” air-conditioning systems (or package systems) with a combined outdoor condenser/evaporator unit are frequently installed in North American residences, offices, and public buildings, but are hard to retrofit (install in a building that was not designed to get it) because of the bulky air ducts needed.

An alternative to packaged systems is the usage of different indoor and outside coils in split systems. Split systems are chosen and extensively used worldwide other than in The United States and Canada. In North America, split systems are usually seen in residential applications, but they are getting appeal in small business structures.

The advantages of ductless cooling systems consist of easy setup, no ductwork, higher zonal control, versatility of control and peaceful operation. [] In area conditioning, the duct losses can account for 30% of energy intake. Making use of minisplit can result in energy cost savings in area conditioning as there are no losses related to ducting.

Indoor units with directional vents install onto walls, suspended from ceilings, or suit the ceiling. Other indoor units install inside the ceiling cavity, so that brief lengths of duct handle air from the indoor system to vents or diffusers around the rooms. Split systems are more efficient and the footprint is typically smaller than the package systems.

Call Now

Call Now