Top Rated Heating & Cooling Pros for heating contractors Glenmora, LA. Call +1 337-238-9689. 24 Hour Calls. Guaranteed Services – Low Prices.
What We Do?
Residential
HVAC Service
Are you looking for home heating or cooling support services that are focused on complete home comfort solutions? The professionals at Southern Air Heating, Cooling & Plumbing sell, install, and fix HVAC units of all makes and models. Get in touch with us today!
Commercial
HVAC Service
Commercial heating and cooling maintenance and repairs are inevitable. At Southern Air Heating, Cooling & Plumbing, we supply a comprehensive variety of heating as well as cooling services to meet every one of your commercial HVAC installation, replacement, repair work, and maintenance requirements.
Emergency
HVAC Service
Emergencies may and do develop, and when they do, rest assured that our team will be there for you! Southern Air Heating, Cooling & Plumbing can easily offer emergency services at any time of the day or night. Never hesitate to call us the moment an emergency occurs!


24 Hour Service
We offer HVAC services 24 hours a day, 7 days a week, 365 days a year. Among our countless service options promises that your comfort requirements are satisfied within your timespan and also even your trickiest heating and air conditioner troubles will be fixed today. Your time is precious– and our team will not keep you waiting!

25 YEARS EXPERIENCE
With over two decades of experience bringing our client’s total satisfaction, Southern Air Heating, Cooling & Plumbing is a premier provider of HVAC services. Serving homes and businesses in , we complete routine maintenance, repair work and new installations modified to your needs and budget demands.
Testimonials
Contact Us
Southern Air Heating, Cooling & Plumbing
203 N 5th St, Leesville, LA 71446, United States
Telephone
+1 337-238-9689
Hours
Open 24 hours
We also provide hvac repair services in the following cities
- furnace cleaning Simpson, LA
- furnace installation Provencal, LA
- furnace replacement Dry Creek, LA
- heating contractors Pitkin, LA
- air conditioning contractor Anacoco, LA
- furnace installation Dry Creek, LA
- furnace service Hornbeck, LA
- ac installation Provencal, LA
- furnace installation Rosepine, LA
- air conditioning contractor Provencal, LA
- heating service Rosepine, LA
- furnace service Glenmora, LA
- furnace service Rosepine, LA
- furnace cleaning Pitkin, LA
- central heat and air Hornbeck, LA
- central air conditioner Burkeville, TX
- central heat and air Boyce, LA
- air conditioner condenser Lena, LA
- ac installation Simpson, LA
- hvac duct cleaning Lena, LA
More About Glenmora, LA
Glenmora is a town in Rapides Parish, Louisiana, United States. It is part of the Alexandria, Louisiana Metropolitan Statistical Area. The population was 1,342 at the 2010 census.
Claude Kirkpatrick, a member of the Louisiana House of Representatives from Jefferson Davis Parish from 1952–1960, a candidate for governor in 1963, and the instigator of Toledo Bend Reservoir was born in Glenmora but moved to Lake Charles when he was six years of age.
Room pressure can be either favorable or unfavorable with regard to outside the room. Favorable pressure happens when there is more air being provided than tired, and is common to decrease the infiltration of outside pollutants. Natural ventilation is a key element in reducing the spread of airborne illnesses such as tuberculosis, the acute rhinitis, influenza and meningitis.
Natural ventilation requires little upkeep and is economical. An a/c system, or a standalone a/c unit, provides cooling and humidity control for all or part of a building. Air conditioned structures typically have actually sealed windows, since open windows would work versus the system planned to maintain constant indoor air conditions.
The percentage of return air comprised of fresh air can generally be manipulated by adjusting the opening of this vent. Normal fresh air intake has to do with 10%. [] Air conditioning and refrigeration are supplied through the removal of heat. Heat can be removed through radiation, convection, or conduction. Refrigeration conduction media such as water, air, ice, and chemicals are referred to as refrigerants.

It is imperative that the cooling horse power is sufficient for the area being cooled. Underpowered air conditioning system will lead to power wastage and inefficient usage. Sufficient horse power is required for any air conditioning unit installed. The refrigeration cycle utilizes four essential components to cool. The system refrigerant starts its cycle in a gaseous state.
From there it enters a heat exchanger (in some cases called a condensing coil or condenser) where it loses energy (heat) to the outside, cools, and condenses into its liquid stage. An (also called metering device) controls the refrigerant liquid to stream at the appropriate rate. The liquid refrigerant is gone back to another heat exchanger where it is enabled to vaporize, for this reason the heat exchanger is often called an evaporating coil or evaporator.
In the process, heat is soaked up from indoors and transferred outdoors, leading to cooling of the structure. In variable climates, the system may include a reversing valve that switches from heating in winter season to cooling in summer. By reversing the circulation of refrigerant, the heatpump refrigeration cycle is changed from cooling to heating or vice versa.
Free cooling systems can have extremely high efficiencies, and are sometimes combined with seasonal thermal energy storage so that the cold of winter season can be utilized for summer air conditioning. Typical storage mediums are deep aquifers or a natural underground rock mass accessed by means of a cluster of small-diameter, heat-exchanger-equipped boreholes.
The heatpump is added-in because the storage acts as a heat sink when the system remains in cooling (as opposed to charging) mode, causing the temperature to slowly increase throughout the cooling season. Some systems consist of an “economizer mode”, which is sometimes called a “free-cooling mode”. When saving money, the control system will open (fully or partially) the outside air damper and close (totally or partially) the return air damper.
When the outside air is cooler than the demanded cool air, this will enable the need to be fulfilled without using the mechanical supply of cooling (typically cooled water or a direct expansion “DX” system), thus saving energy. The control system can compare the temperature of the outdoors air vs.
In both cases, the outside air must be less energetic than the return air for the system to enter the economizer mode. Central, “all-air” air-conditioning systems (or plan systems) with a combined outside condenser/evaporator unit are often set up in North American homes, offices, and public structures, however are tough to retrofit (set up in a building that was not designed to receive it) because of the bulky duct needed.

An option to packaged systems is using different indoor and outside coils in split systems. Split systems are preferred and extensively utilized worldwide except in North America. In North America, split systems are frequently seen in domestic applications, but they are getting popularity in little industrial structures.
The benefits of ductless cooling systems consist of simple setup, no ductwork, higher zonal control, flexibility of control and peaceful operation. [] In space conditioning, the duct losses can represent 30% of energy usage. Making use of minisplit can result in energy cost savings in area conditioning as there are no losses associated with ducting.
Indoor systems with directional vents install onto walls, suspended from ceilings, or suit the ceiling. Other indoor systems mount inside the ceiling cavity, so that short lengths of duct deal with air from the indoor unit to vents or diffusers around the rooms. Split systems are more efficient and the footprint is typically smaller than the bundle systems.
