Top Rated HVAC Experts for hvac contractors near me Luling, LA. Phone +1 800-349-3918. 24 Hour Calls. Guaranteed Services – Low Prices.
What We Do?
Residential
HVAC Service
Are you looking for residential heating and cooling support services that are focused on total home comfort remedies? The professionals at Keefe's Air Conditioning, Heating, & Electrical sell, install, and repair HVAC units of all makes and models. Get in touch with us today!
Commercial
HVAC Service
Commercial heating and cooling maintenance and repairs are unavoidable. At Keefe's Air Conditioning, Heating, & Electrical, we supply a comprehensive range of heating as well as cooling solutions to meet every one of your commercial HVAC installation, replacement, repair, and servicing needs.
Emergency
HVAC Service
Emergencies will and definitely do occur, and when they do, rest comfortably that our team will be there for you! Keefe's Air Conditioning, Heating, & Electrical is able to provide emergency support at any time of the day or night. Don’t hesitate to get in touch with us the second an emergency happens!


24 Hour Service
We deliver HVAC services 24 hours a day, 7 days a week, 365 days a year. One of our many service options ensures that your comfort requirements are fulfilled within your timespan and that even your most worrisome heating and air conditioner troubles will be fixed today. Your time is precious– and our experts will never keep you waiting!

25 YEARS EXPERIENCE
With over two decades of experience bringing our client’s total satisfaction, Keefe's Air Conditioning, Heating, & Electrical is a top provider of HVAC services. Serving homes and businesses within , we complete routine maintenance, repairs and new installations modified to your needs and budget demands.
Testimonials
Contact Us
Keefe’s Air Conditioning, Heating, & Electrical
1919 Enterprise Dr, Harvey, LA 70058, United States
Telephone
+1 800-349-3918
Hours
Open 24 hours
We also provide hvac repair services in the following cities
More About Luling, LA
Luling is a census-designated place (CDP) in St. Charles Parish, Louisiana, United States. The population was 11,512 at the 2000 census and 12,119 at the 2010 census
Luling is located at 29°54′48″N 90°21′50″W / 29.91333°N 90.36389°W / 29.91333; -90.36389 (29.913260, -90.364008)[1] and has an elevation of 7 feet (2.1 m).[2]
Room pressure can be either favorable or negative with respect to outside the room. Positive pressure happens when there is more air being provided than tired, and is typical to reduce the seepage of outside contaminants. Natural ventilation is a key factor in decreasing the spread of air-borne diseases such as tuberculosis, the cold, influenza and meningitis.
Natural ventilation requires little upkeep and is inexpensive. A cooling system, or a standalone air conditioning unit, offers cooling and humidity control for all or part of a structure. Air conditioned buildings frequently have sealed windows, due to the fact that open windows would work against the system planned to keep continuous indoor air conditions.
The portion of return air made up of fresh air can generally be controlled by changing the opening of this vent. Normal fresh air consumption has to do with 10%. [] A/c and refrigeration are provided through the elimination of heat. Heat can be gotten rid of through radiation, convection, or conduction. Refrigeration conduction media such as water, air, ice, and chemicals are referred to as refrigerants.

It is important that the cooling horse power is enough for the location being cooled. Underpowered air conditioning system will result in power waste and ineffective use. Appropriate horsepower is required for any air conditioning system set up. The refrigeration cycle uses 4 essential aspects to cool. The system refrigerant begins its cycle in a gaseous state.
From there it enters a heat exchanger (often called a condensing coil or condenser) where it loses energy (heat) to the outdoors, cools, and condenses into its liquid phase. An (also called metering device) controls the refrigerant liquid to flow at the appropriate rate. The liquid refrigerant is returned to another heat exchanger where it is permitted to vaporize, hence the heat exchanger is frequently called an evaporating coil or evaporator.
In the procedure, heat is taken in from inside your home and transferred outdoors, resulting in cooling of the building. In variable environments, the system may consist of a reversing valve that switches from heating in winter season to cooling in summer. By reversing the circulation of refrigerant, the heat pump refrigeration cycle is changed from cooling to heating or vice versa.
Free cooling systems can have really high performances, and are sometimes integrated with seasonal thermal energy storage so that the cold of winter season can be used for summertime a/c. Common storage mediums are deep aquifers or a natural underground rock mass accessed by means of a cluster of small-diameter, heat-exchanger-equipped boreholes.
The heatpump is added-in because the storage acts as a heat sink when the system remains in cooling (rather than charging) mode, causing the temperature to gradually increase throughout the cooling season. Some systems consist of an “economizer mode”, which is sometimes called a “free-cooling mode”. When economizing, the control system will open (completely or partially) the outdoors air damper and close (totally or partially) the return air damper.
When the outdoors air is cooler than the required cool air, this will permit the need to be satisfied without using the mechanical supply of cooling (normally chilled water or a direct growth “DX” unit), thus saving energy. The control system can compare the temperature level of the outdoors air vs.
In both cases, the outside air needs to be less energetic than the return air for the system to go into the economizer mode. Central, “all-air” air-conditioning systems (or package systems) with a combined outside condenser/evaporator system are typically installed in North American houses, workplaces, and public buildings, but are tough to retrofit (install in a structure that was not designed to receive it) due to the fact that of the bulky air ducts needed.

An option to packaged systems is making use of different indoor and outdoor coils in split systems. Split systems are chosen and commonly used around the world other than in North America. In North America, split systems are usually seen in property applications, however they are acquiring popularity in little industrial structures.
The benefits of ductless cooling systems include simple installation, no ductwork, higher zonal control, flexibility of control and quiet operation. [] In space conditioning, the duct losses can account for 30% of energy intake. The use of minisplit can result in energy savings in space conditioning as there are no losses connected with ducting.
Indoor systems with directional vents mount onto walls, suspended from ceilings, or suit the ceiling. Other indoor units mount inside the ceiling cavity, so that brief lengths of duct handle air from the indoor system to vents or diffusers around the rooms. Split systems are more effective and the footprint is normally smaller sized than the package systems.