Top Rated AC & Heating Pros for hvac air conditioning Travelers Rest, SC. Call +1 864-392-5650. 24 Hour Calls. Guaranteed Services – Low Prices.
What We Do?
Residential
HVAC Service
Are you looking for residential heating or cooling support services that are focused on home comfort remedies? The specialists at Corley Plumbing Air Electric sell, install, as well as repair HVAC systems of all makes and models. Reach out to us today!
Commercial
HVAC Service
Commercial heating and cooling maintenance and repairs are unavoidable. At Corley Plumbing Air Electric, we supply an extensive range of heating as well as cooling services to meet each of your commercial HVAC installation, replacement, repair, and routine maintenance requirements.
Emergency
HVAC Service
Emergencies can and do develop, when they do, rest comfortably that our experts will be there for you! Corley Plumbing Air Electric can offer emergency assistance at any moment of the day or night. Never hesitate to get in touch with us the minute an emergency happens!


24 Hour Service
We provide HVAC services 24 hours a day, 7 days a week, 365 days a year. One of our various service options ensures that your comfort needs are satisfied within your timespan and also even your most worrisome heating or air conditioner issues will be fixed today. Your time is precious– and our team won’t keep you waiting!

25 YEARS EXPERIENCE
With over two decades of experience bringing our client’s total satisfaction, Corley Plumbing Air Electric is a premier provider of HVAC services. Serving homes and businesses throughout , we complete regular servicing, repairs and new installations customized to your needs and budget demands.
Testimonials
Contact Us
Corley Plumbing Air Electric
8501 Pelham Rd, Greenville, SC 29615, United States
Telephone
+1 864-392-5650
Hours
Open 24 hours
We also provide hvac repair services in the following cities
- natural gas heater repair near me Duncan, SC
- hvac repair Fountain Inn, SC
- gas stove heater repair near me Easley, SC
- hvac repair Greenville, SC
- hvac Greenville, SC
- gas heater repair service Woodruff, SC
- hvac contractor Duncan, SC
- hvac company Duncan, SC
- gas floor heater repair Reidville, SC
- who repairs the empire gas ventless heater Reidville, SC
- air conditioning company Greenville, SC
- repair shops that service non-vented gas heaters Startex, SC
- allied commercial hvac Taylors, SC
- hvac company Taylors, SC
- commercial express hvac Woodruff, SC
- natural gas heater repair near me Spartanburg, SC
- commercial hvac companies Mauldin, SC
- propane gas heater repairs Williamston, SC
- home air conditioning Wellford, SC
- 2 ton hvac unit Wellford, SC
More About Travelers Rest, SC
Travelers Rest is a city in Greenville County, South Carolina, United States. The population was 4,576 at the 2010 census,[4] up from 4,099 in 2000. The population was an estimated 5,253 in 2018. It is part of the Greenville–Mauldin–Easley Metropolitan Statistical Area. Travelers Rest is located between the Blue Ridge Mountains and Greenville, the primary city of the Upstate region of South Carolina. The campus of Furman University is located just south of the city limits of Travelers Rest, but the university retains a Greenville address based on its ZIP code.
Space pressure can be either positive or negative with respect to outside the space. Positive pressure occurs when there is more air being provided than tired, and is typical to lower the infiltration of outdoors contaminants. Natural ventilation is an essential factor in lowering the spread of air-borne illnesses such as tuberculosis, the acute rhinitis, influenza and meningitis.
Natural ventilation requires little upkeep and is low-cost. A cooling system, or a standalone a/c, offers cooling and humidity control for all or part of a building. Air conditioned structures often have actually sealed windows, because open windows would work versus the system intended to maintain continuous indoor air conditions.
The portion of return air comprised of fresh air can normally be manipulated by adjusting the opening of this vent. Common fresh air consumption is about 10%. [] Cooling and refrigeration are supplied through the elimination of heat. Heat can be gotten rid of through radiation, convection, or conduction. Refrigeration conduction media such as water, air, ice, and chemicals are referred to as refrigerants.

It is vital that the air conditioning horsepower is sufficient for the area being cooled. Underpowered cooling system will result in power waste and inefficient use. Appropriate horsepower is needed for any a/c set up. The refrigeration cycle uses 4 necessary aspects to cool. The system refrigerant starts its cycle in a gaseous state.
From there it enters a heat exchanger (in some cases called a condensing coil or condenser) where it loses energy (heat) to the outside, cools, and condenses into its liquid stage. An (also called metering gadget) controls the refrigerant liquid to flow at the proper rate. The liquid refrigerant is gone back to another heat exchanger where it is enabled to evaporate, for this reason the heat exchanger is often called an evaporating coil or evaporator.
While doing so, heat is absorbed from indoors and moved outdoors, resulting in cooling of the building. In variable environments, the system may include a reversing valve that changes from heating in winter to cooling in summertime. By reversing the circulation of refrigerant, the heatpump refrigeration cycle is altered from cooling to heating or vice versa.
Free cooling systems can have really high performances, and are in some cases integrated with seasonal thermal energy storage so that the cold of winter can be utilized for summer cooling. Typical storage mediums are deep aquifers or a natural underground rock mass accessed through a cluster of small-diameter, heat-exchanger-equipped boreholes.
The heatpump is added-in since the storage serves as a heat sink when the system is in cooling (as opposed to charging) mode, causing the temperature to gradually increase during the cooling season. Some systems include an “economizer mode”, which is often called a “free-cooling mode”. When saving money, the control system will open (fully or partially) the outside air damper and close (completely or partially) the return air damper.
When the outdoors air is cooler than the required cool air, this will allow the demand to be satisfied without utilizing the mechanical supply of cooling (typically cooled water or a direct expansion “DX” system), hence saving energy. The control system can compare the temperature of the outside air vs.
In both cases, the outdoors air should be less energetic than the return air for the system to go into the economizer mode. Central, “all-air” air-conditioning systems (or package systems) with a combined outside condenser/evaporator unit are often set up in North American houses, workplaces, and public buildings, but are difficult to retrofit (set up in a structure that was not created to receive it) because of the large air ducts required.

An option to packaged systems is making use of different indoor and outside coils in split systems. Split systems are chosen and widely used worldwide except in The United States and Canada. In North America, split systems are most frequently seen in residential applications, however they are getting appeal in little commercial buildings.
The advantages of ductless air conditioning systems include easy setup, no ductwork, greater zonal control, flexibility of control and peaceful operation. [] In space conditioning, the duct losses can account for 30% of energy intake. Using minisplit can result in energy cost savings in area conditioning as there are no losses connected with ducting.
Indoor units with directional vents install onto walls, suspended from ceilings, or suit the ceiling. Other indoor units mount inside the ceiling cavity, so that brief lengths of duct deal with air from the indoor unit to vents or diffusers around the spaces. Split systems are more effective and the footprint is normally smaller than the plan systems.
