Top Rated AC & Heating Experts for heating and air companies near me Travelers Rest, SC. Dial +1 864-392-5650. 24 Hour Calls. Guaranteed Services – Low Prices.
What We Do?
Residential
HVAC Service
Are you looking for home heating or cooling services that are centered on complete home comfort solutions? The specialists at Corley Plumbing Air Electric sell, install, and also fix HVAC units of all makes and models. Reach out to us today!
Commercial
HVAC Service
Commercial heating and cooling maintenance and repairs are inevitable. At Corley Plumbing Air Electric, we deliver a comprehensive variety of heating as well as cooling support services to meet every one of your commercial HVAC installation, replacement, repair, and servicing demands.
Emergency
HVAC Service
Emergencies will and definitely do occur, and when they do, rest assured that we will will be there for you! Corley Plumbing Air Electric can deliver emergency services at any time of the day or night. Never hesitate to get in touch with us the minute an emergency happens!


24 Hour Service
We provide HVAC services 24 hours a day, 7 days a week, 365 days a year. One of our various service options ensures that your comfort needs are achieved within your time frame and that even your trickiest heating and air conditioner issues will be fixed today. Your time is precious– and our team will never keep you waiting!

25 YEARS EXPERIENCE
With over two decades of experience bringing our customer’s complete satisfaction, Corley Plumbing Air Electric is a premier provider of HVAC services. Serving residential properties and businesses in , we complete regular servicing, repairs as well as new installations tailored to your needs and budget demands.
Testimonials
Contact Us
Corley Plumbing Air Electric
8501 Pelham Rd, Greenville, SC 29615, United States
Telephone
+1 864-392-5650
Hours
Open 24 hours
We also provide hvac repair services in the following cities
- hvac company Simpsonville, SC
- american standard hvac commercial Williamston, SC
- hvac contractor Easley, SC
- hvac air conditioning Pelzer, SC
- hvac contractor Duncan, SC
- bryant commercial hvac Piedmont, SC
- hvac contractors Gray Court, SC
- bryant commercial hvac Duncan, SC
- heating and air conditioning Wellford, SC
- propane gas heater repairs Duncan, SC
- propane gas heater repairs Fountain Inn, SC
- natural gas heater repair near me Greer, SC
- hvac air conditioning Easley, SC
- gas stove heater repair near me Travelers Rest, SC
- gas stove heater repair near me Lyman, SC
- gas floor heater repair Lyman, SC
- air conditioning service Mauldin, SC
- gas stove heater repair near me Easley, SC
- commercial hvac companies Williamston, SC
- hvac Lyman, SC
More About Travelers Rest, SC
Travelers Rest is a city in Greenville County, South Carolina, United States. The population was 4,576 at the 2010 census,[4] up from 4,099 in 2000. The population was an estimated 5,253 in 2018. It is part of the Greenville–Mauldin–Easley Metropolitan Statistical Area. Travelers Rest is located between the Blue Ridge Mountains and Greenville, the primary city of the Upstate region of South Carolina. The campus of Furman University is located just south of the city limits of Travelers Rest, but the university retains a Greenville address based on its ZIP code.
Numerous inventions within this time frame preceded the beginnings of first convenience cooling system, which was developed in 1902 by Alfred Wolff (Cooper, 2003) for the New York Stock Exchange, while Willis Provider equipped the Sacketts-Wilhems Printing Business with the procedure Air Conditioning unit the same year. Coyne College was the very first school to offer HVAC training in 1899.
Heating systems are home appliances whose function is to generate heat (i.e. heat) for the building. This can be done by means of main heating. Such a system consists of a boiler, heater, or heatpump to heat water, steam, or air in a central place such as a heater space in a home, or a mechanical space in a large structure.

Heating units exist for numerous types of fuel, consisting of strong fuels, liquids, and gases. Another type of heat source is electrical power, typically warming ribbons made up of high resistance wire (see Nichrome). This concept is likewise used for baseboard heating units and portable heaters. Electrical heaters are typically utilized as backup or additional heat for heat pump systems.
Heatpump can draw out heat from numerous sources, such as ecological air, exhaust air from a structure, or from the ground. Heatpump transfer heat from outside the structure into the air inside. Initially, heat pump HEATING AND COOLING systems were just utilized in moderate environments, however with enhancements in low temperature level operation and reduced loads due to more effective houses, they are increasing in appeal in cooler climates.


Most modern-day hot water boiler heating systems have a circulator, which is a pump, to move hot water through the circulation system (instead of older gravity-fed systems). The heat can be moved to the surrounding air utilizing radiators, warm water coils (hydro-air), or other heat exchangers. The radiators might be installed on walls or set up within the flooring to produce flooring heat.
The heated water can also supply an auxiliary heat exchanger to provide warm water for bathing and cleaning. Warm air systems disperse heated air through duct systems of supply and return air through metal or fiberglass ducts. Numerous systems use the very same ducts to disperse air cooled by an evaporator coil for air conditioning.
Incomplete combustion occurs when there is inadequate oxygen; the inputs are fuels consisting of numerous pollutants and the outputs are damaging byproducts, most dangerously carbon monoxide, which is an unappetizing and odor free gas with major negative health impacts. Without appropriate ventilation, carbon monoxide can be lethal at concentrations of 1000 ppm (0.1%).
Carbon monoxide binds with hemoglobin in the blood, forming carboxyhemoglobin, lowering the blood’s capability to transport oxygen. The main health issues connected with carbon monoxide gas direct exposure are its cardiovascular and neurobehavioral impacts. Carbon monoxide can trigger atherosclerosis (the hardening of arteries) and can also trigger cardiac arrest. Neurologically, carbon monoxide gas exposure decreases hand to eye coordination, vigilance, and constant performance.
Ventilation is the procedure of altering or replacing air in any area to manage temperature or eliminate any mix of wetness, odors, smoke, heat, dust, air-borne bacteria, or co2, and to replenish oxygen. Ventilation consists of both the exchange of air with the outdoors as well as flow of air within the building.
Approaches for aerating a building may be divided into mechanical/forced and natural types. HVAC ventilation exhaust for a 12-story building Mechanical, or required, ventilation is supplied by an air handler (AHU) and utilized to control indoor air quality. Excess humidity, smells, and impurities can typically be managed via dilution or replacement with outside air.
Kitchen areas and restrooms normally have mechanical exhausts to manage odors and in some cases humidity. Aspects in the style of such systems consist of the circulation rate (which is a function of the fan speed and exhaust vent size) and sound level. Direct drive fans are available for many applications, and can reduce maintenance requirements.
Due to the fact that hot air rises, ceiling fans may be utilized to keep a space warmer in the winter season by distributing the warm stratified air from the ceiling to the flooring. Natural ventilation is the ventilation of a structure with outdoors air without utilizing fans or other mechanical systems. It can be by means of operable windows, louvers, or trickle vents when areas are little and the architecture allows.
Natural ventilation plans can use extremely little energy, but care should be required to guarantee comfort. In warm or damp environments, preserving thermal comfort entirely via natural ventilation may not be possible. Cooling systems are used, either as backups or supplements. Air-side economizers also use outdoors air to condition areas, however do so using fans, ducts, dampers, and control systems to introduce and distribute cool outdoor air when suitable.
