Find Us At

8501 Pelham Rd
Greenville, SC 29615

Call Us At

+1 864-392-5650

Business Hours

Open 24 hours

Top Heating & Cooling Pros for commercial express hvac Williamston, SC. Call +1 864-392-5650. 24 Hour Calls. Guaranteed Services – Low Prices.

What We Do?

Residential
HVAC Service

Are you searching for home heating and cooling support services that are focused on total home comfort remedies? The specialists at Corley Plumbing Air Electric sell, install, and also repair HVAC units of all makes and models. Contact us today!

Commercial
HVAC Service

Commercial heating and cooling maintenance and repairs are unavoidable. At Corley Plumbing Air Electric, we supply an extensive range of heating as well as cooling services to meet each of your commercial HVAC installation, replacement, repair, and maintenance requirements.

Emergency
HVAC Service

Emergencies may and do develop, when they do, rest assured that our experts will be there for you! Corley Plumbing Air Electric can easily provide emergency services at any time of the day or night. Never hesitate to contact us the second an emergency happens!

24 Hour Service

We offer HVAC services 24 hours a day, 7 days a week, 365 days a year. Among our various service options promises that your comfort requirements are achieved within your time frame and that even your trickiest heating or air conditioner troubles will be resolved today. Your time is precious– and our company will never keep you waiting!

25 YEARS EXPERIENCE

With over two decades of experience bringing our client’s complete satisfaction, Corley Plumbing Air Electric is a leading provider of HVAC services. Serving residential properties and businesses in , we perform routine servicing, repair work as well as new installations tailored to your needs and budget demands.

Testimonials

Contact Us

Corley Plumbing Air Electric

8501 Pelham Rd, Greenville, SC 29615, United States

Telephone

+1 864-392-5650

Hours

Open 24 hours

More About Williamston, SC

Williamston is a town in Anderson County, South Carolina, United States. The population was 3,934 at the 2010 census.[3][4]

Williamston is located in northeastern Anderson County at 34°37′4″N 82°28′45″W / 34.61778°N 82.47917°W / 34.61778; -82.47917 (34.617699, -82.479256).[5] The twin towns of Pelzer and West Pelzer are 2 miles (3 km) to the north. Anderson, the county seat, is 15 miles (24 km) to the southwest.

Several creations within this time frame preceded the starts of very first convenience cooling system, which was created in 1902 by Alfred Wolff (Cooper, 2003) for the New York Stock Exchange, while Willis Provider geared up the Sacketts-Wilhems Printing Business with the procedure AC system the same year. Coyne College was the first school to offer HEATING AND COOLING training in 1899.

Heating units are devices whose function is to create heat (i.e. heat) for the structure. This can be done by means of main heating. Such a system includes a boiler, heater, or heatpump to heat water, steam, or air in a main location such as a furnace room in a house, or a mechanical space in a big building.

Heating units exist for various kinds of fuel, consisting of solid fuels, liquids, and gases. Another kind of heat source is electricity, generally heating up ribbons composed of high resistance wire (see Nichrome). This concept is also utilized for baseboard heating units and portable heating systems. Electrical heating units are frequently used as backup or additional heat for heatpump systems.

Heatpump can draw out heat from various sources, such as ecological air, exhaust air from a building, or from the ground. Heat pumps move heat from outside the structure into the air within. At first, heatpump A/C systems were just used in moderate environments, however with enhancements in low temperature level operation and minimized loads due to more effective homes, they are increasing in popularity in cooler climates.

The majority of contemporary warm water boiler heating unit have a circulator, which is a pump, to move hot water through the circulation system (instead of older gravity-fed systems). The heat can be moved to the surrounding air using radiators, hot water coils (hydro-air), or other heat exchangers. The radiators may be installed on walls or set up within the flooring to produce floor heat.

The heated water can also supply an auxiliary heat exchanger to supply hot water for bathing and washing. Warm air systems disperse heated air through duct work systems of supply and return air through metal or fiberglass ducts. Many systems use the same ducts to disperse air cooled by an evaporator coil for a/c.

Incomplete combustion happens when there is inadequate oxygen; the inputs are fuels including different contaminants and the outputs are hazardous by-products, the majority of precariously carbon monoxide, which is a tasteless and odor-free gas with serious unfavorable health impacts. Without appropriate ventilation, carbon monoxide can be deadly at concentrations of 1000 ppm (0.1%).

Carbon monoxide binds with hemoglobin in the blood, forming carboxyhemoglobin, reducing the blood’s capability to transfer oxygen. The main health issues connected with carbon monoxide direct exposure are its cardiovascular and neurobehavioral results. Carbon monoxide can cause atherosclerosis (the hardening of arteries) and can also set off cardiovascular disease. Neurologically, carbon monoxide exposure minimizes hand to eye coordination, alertness, and continuous performance.

Ventilation is the process of altering or changing air in any area to control temperature level or get rid of any mix of moisture, smells, smoke, heat, dust, air-borne bacteria, or carbon dioxide, and to replenish oxygen. Ventilation includes both the exchange of air with the outside along with blood circulation of air within the building.

Methods for ventilating a building may be divided into mechanical/forced and natural types. HEATING AND COOLING ventilation exhaust for a 12-story building Mechanical, or forced, ventilation is offered by an air handler (AHU) and utilized to control indoor air quality. Excess humidity, odors, and impurities can typically be controlled through dilution or replacement with outside air.

Bathroom and kitchens usually have mechanical exhausts to manage smells and sometimes humidity. Consider the design of such systems include the circulation rate (which is a function of the fan speed and exhaust vent size) and sound level. Direct drive fans are available for many applications, and can minimize upkeep needs.

Due to the fact that hot air rises, ceiling fans might be utilized to keep a room warmer in the winter season by distributing the warm stratified air from the ceiling to the floor. Natural ventilation is the ventilation of a building with outdoors air without utilizing fans or other mechanical systems. It can be by means of operable windows, louvers, or drip vents when areas are small and the architecture permits.

Natural ventilation plans can use very little energy, but care needs to be taken to make sure convenience. In warm or damp climates, maintaining thermal comfort entirely by means of natural ventilation might not be possible. A/c systems are used, either as backups or supplements. Air-side economizers also use outside air to condition spaces, but do so using fans, ducts, dampers, and control systems to present and disperse cool outside air when appropriate.

Call Now

Call Now