Best Heating & Cooling Pros for bryant hvac High Point, NC. Phone +1 336-296-1100. 24 Hour Calls. Guaranteed Services – Low Prices.
What We Do?
Residential
HVAC Service
Are you looking for home heating or cooling services that are focused on total home comfort remedies? The specialists at Go Green Plumbing, Heating and Air sell, install, and also fix HVAC units of all makes and models. Reach out to us today!
Commercial
HVAC Service
Commercial cooling and heating maintenance and repairs are unavoidable. At Go Green Plumbing, Heating and Air, we provide a comprehensive range of heating and cooling support services to meet each of your commercial HVAC installation, replacement, repair work, and servicing demands.
Emergency
HVAC Service
Emergencies may and do develop, and when they do, rest assured that our team will be there for you! Go Green Plumbing, Heating and Air can easily deliver emergency support at any time of the day or night. Don’t hesitate to get in touch with us the minute an emergency happens!


24 Hour Service
We provide HVAC services 24 hours a day, 7 days a week, 365 days a year. One of our various service options promises that your comfort needs are met within your time frame and that even your most worrisome heating and air conditioner concerns will be solved today. Your time is precious– and our team will never keep you waiting!

25 YEARS EXPERIENCE
With over two decades of experience bringing our customer’s complete satisfaction, Go Green Plumbing, Heating and Air is a top provider of HVAC services. Serving residential properties and businesses throughout , we complete routine maintenance, repairs and new installations customized to your needs and budget demands.
Testimonials
Contact Us
Go Green Plumbing, Heating and Air
3714 Alliance Dr Suite 304, Greensboro, NC 27407, United States
Telephone
+1 336-296-1100
Hours
Open 24 hours
We also provide hvac repair services in the following cities
- heat pump hvac High Point, NC
- carrier hvac Greensboro, NC
- carrier hvac Kernersville, NC
- cost of new hvac system Jamestown, NC
- goodman hvac Gibsonville, NC
- carrier hvac Gibsonville, NC
- home hvac system Greensboro, NC
- high velocity hvac Burlington, NC
- goodman hvac Jamestown, NC
- horizon hvac Mcleansville, NC
More About High Point, NC
High Point is a city located in the Piedmont Triad region of the U.S. state of North Carolina. Most of the city is located in Guilford County, with portions extending into neighboring Randolph, Davidson, and Forsyth counties. High Point is North Carolina’s only city that extends into four counties. As of the 2010 census the city had a total population of 104,371,[4] with an estimated population of 112,791 in 2019.[2] High Point is currently the ninth-largest municipality in North Carolina, and the 259th largest city in America.
Major industries in High Point include furniture, textiles, and bus manufacturing. The city’s official slogan is “North Carolina’s International City” due to the semi-annual High Point Furniture Market that attracts 100,000 exhibitors and buyers from around the world.
Room pressure can be either positive or negative with regard to outside the room. Favorable pressure happens when there is more air being provided than exhausted, and prevails to decrease the seepage of outdoors contaminants. Natural ventilation is an essential consider minimizing the spread of airborne health problems such as tuberculosis, the common cold, influenza and meningitis.
Natural ventilation needs little maintenance and is low-cost. An air conditioning system, or a standalone air conditioning unit, offers cooling and humidity control for all or part of a building. Air conditioned structures frequently have actually sealed windows, since open windows would work versus the system planned to maintain constant indoor air conditions.
The portion of return air comprised of fresh air can typically be controlled by adjusting the opening of this vent. Common fresh air intake is about 10%. [] Cooling and refrigeration are offered through the removal of heat. Heat can be eliminated through radiation, convection, or conduction. Refrigeration conduction media such as water, air, ice, and chemicals are described as refrigerants.

It is essential that the cooling horse power suffices for the location being cooled. Underpowered a/c system will cause power waste and inefficient use. Appropriate horse power is required for any air conditioning unit set up. The refrigeration cycle utilizes four essential aspects to cool. The system refrigerant starts its cycle in a gaseous state.
From there it gets in a heat exchanger (sometimes called a condensing coil or condenser) where it loses energy (heat) to the outside, cools, and condenses into its liquid stage. An (likewise called metering gadget) manages the refrigerant liquid to stream at the appropriate rate. The liquid refrigerant is gone back to another heat exchanger where it is allowed to vaporize, for this reason the heat exchanger is often called an evaporating coil or evaporator.
At the same time, heat is soaked up from inside your home and moved outdoors, resulting in cooling of the structure. In variable environments, the system might include a reversing valve that changes from heating in winter season to cooling in summertime. By reversing the flow of refrigerant, the heat pump refrigeration cycle is altered from cooling to heating or vice versa.
Free cooling systems can have extremely high effectiveness, and are often integrated with seasonal thermal energy storage so that the cold of winter season can be utilized for summer season air conditioning. Common storage mediums are deep aquifers or a natural underground rock mass accessed by means of a cluster of small-diameter, heat-exchanger-equipped boreholes.
The heatpump is added-in due to the fact that the storage serves as a heat sink when the system remains in cooling (instead of charging) mode, causing the temperature level to gradually increase throughout the cooling season. Some systems include an “economizer mode”, which is sometimes called a “free-cooling mode”. When saving money, the control system will open (completely or partially) the outside air damper and close (fully or partly) the return air damper.
When the outside air is cooler than the demanded cool air, this will permit the need to be satisfied without using the mechanical supply of cooling (usually chilled water or a direct growth “DX” unit), therefore conserving energy. The control system can compare the temperature of the outside air vs.
In both cases, the outside air must be less energetic than the return air for the system to go into the economizer mode. Central, “all-air” air-conditioning systems (or package systems) with a combined outdoor condenser/evaporator unit are frequently set up in North American houses, workplaces, and public structures, but are hard to retrofit (install in a building that was not designed to receive it) due to the fact that of the large duct needed.

An option to packaged systems is the usage of separate indoor and outdoor coils in split systems. Split systems are preferred and extensively used around the world other than in The United States and Canada. In North America, divided systems are usually seen in residential applications, however they are acquiring appeal in little business structures.
The advantages of ductless air conditioning systems include simple installation, no ductwork, greater zonal control, flexibility of control and quiet operation. [] In space conditioning, the duct losses can account for 30% of energy consumption. The use of minisplit can lead to energy savings in area conditioning as there are no losses related to ducting.
Indoor units with directional vents mount onto walls, suspended from ceilings, or fit into the ceiling. Other indoor systems install inside the ceiling cavity, so that brief lengths of duct deal with air from the indoor system to vents or diffusers around the spaces. Split systems are more effective and the footprint is generally smaller than the bundle systems.
