What We Do?

Residential
HVAC Service

Are you searching for residential heating and cooling support services that are focused on home comfort remedies? The professionals at Velocity Air Conditioning sell, install, and also fix HVAC units of all makes and models. Call us today!

Commercial
HVAC Service

Commercial heating and cooling repairs are unavoidable. At Velocity Air Conditioning, we supply an extensive variety of heating as well as cooling services to meet each of your commercial HVAC installation, replacement, repair, and servicing demands.

Emergency
HVAC Service

Emergencies may and definitely do happen, and when they do, rest assured that our team will be there for you! Velocity Air Conditioning can provide emergency assistance at any time of the day or night. Don’t hesitate to get in touch with us the minute an emergency occurs!

24 Hour Service

We offer HVAC services 24 hours a day, 7 days a week, 365 days a year. One of our many service options guarantees that your comfort demands are fulfilled within your timespan and that even your trickiest heating or air conditioner problems will be fixed today. Your time is valuable– and our company will never keep you waiting!

25 YEARS EXPERIENCE

With over two decades of experience bringing our client’s total satisfaction, Velocity Air Conditioning is a leading provider of HVAC services. Serving residential properties and businesses within , we complete regular servicing, repair work and also new installations tailored to your needs and budget guidelines.

Testimonials

Contact Us

Velocity Air Conditioning

13130 56th Ct N #605, Clearwater, FL 33760, United States

Telephone

+1 727-768-7882

Hours

Open 24 hours

More About Tampa, FL

Tampa (US: /ˈtæmpə/) is a major city in, and the county seat of, Hillsborough County, Florida, United States.[11] It is on the west coast of Florida on Tampa Bay, near the Gulf of Mexico. Tampa is the largest city in the Tampa Bay Area. With a population of 399,700 in 2019, Tampa is the third-largest city in Florida, after Miami and Jacksonville. The bay’s port is the largest in the state, near downtown’s Channel District. Bayshore Boulevard runs along the bay, and is east of the historic Hyde Park neighborhood.

Numerous inventions within this time frame preceded the starts of first convenience a/c system, which was designed in 1902 by Alfred Wolff (Cooper, 2003) for the New York Stock Exchange, while Willis Provider equipped the Sacketts-Wilhems Printing Business with the process Air Conditioner system the very same year. Coyne College was the very first school to provide HVAC training in 1899.

Heaters are appliances whose function is to generate heat (i.e. heat) for the building. This can be done by means of central heating. Such a system consists of a boiler, furnace, or heat pump to heat water, steam, or air in a main area such as a heating system space in a house, or a mechanical space in a large building.

Heating units exist for various kinds of fuel, including strong fuels, liquids, and gases. Another type of heat source is electrical power, generally heating ribbons composed of high resistance wire (see Nichrome). This principle is also utilized for baseboard heaters and portable heaters. Electrical heaters are frequently used as backup or additional heat for heatpump systems.

Heatpump can draw out heat from numerous sources, such as environmental air, exhaust air from a structure, or from the ground. Heat pumps move heat from outside the structure into the air within. Initially, heat pump HVAC systems were just utilized in moderate environments, however with improvements in low temperature level operation and minimized loads due to more efficient houses, they are increasing in appeal in cooler environments.

A lot of contemporary warm water boiler heating systems have a circulator, which is a pump, to move warm water through the distribution system (rather than older gravity-fed systems). The heat can be moved to the surrounding air utilizing radiators, hot water coils (hydro-air), or other heat exchangers. The radiators might be mounted on walls or set up within the flooring to produce floor heat.

The heated water can likewise supply an auxiliary heat exchanger to provide hot water for bathing and washing. Warm air systems distribute heated air through duct work systems of supply and return air through metal or fiberglass ducts. Numerous systems utilize the same ducts to distribute air cooled by an evaporator coil for air conditioning.

Incomplete combustion happens when there is insufficient oxygen; the inputs are fuels including different impurities and the outputs are harmful by-products, many precariously carbon monoxide, which is an unsavory and odorless gas with severe unfavorable health results. Without correct ventilation, carbon monoxide can be deadly at concentrations of 1000 ppm (0.1%).

Carbon monoxide gas binds with hemoglobin in the blood, forming carboxyhemoglobin, decreasing the blood’s capability to transfer oxygen. The main health concerns related to carbon monoxide direct exposure are its cardiovascular and neurobehavioral effects. Carbon monoxide can cause atherosclerosis (the hardening of arteries) and can likewise activate heart attacks. Neurologically, carbon monoxide gas direct exposure minimizes hand to eye coordination, caution, and continuous efficiency.

Ventilation is the procedure of altering or replacing air in any area to manage temperature level or eliminate any mix of wetness, odors, smoke, heat, dust, airborne bacteria, or co2, and to renew oxygen. Ventilation includes both the exchange of air with the outdoors in addition to circulation of air within the structure.

Approaches for ventilating a building may be divided into mechanical/forced and natural types. A/C ventilation exhaust for a 12-story building Mechanical, or forced, ventilation is provided by an air handler (AHU) and used to control indoor air quality. Excess humidity, odors, and pollutants can typically be controlled by means of dilution or replacement with outdoors air.

Kitchens and bathrooms usually have mechanical exhausts to control odors and in some cases humidity. Factors in the style of such systems include the circulation rate (which is a function of the fan speed and exhaust vent size) and sound level. Direct drive fans are offered for lots of applications, and can lower maintenance requirements.

Since hot air increases, ceiling fans may be utilized to keep a room warmer in the winter season by flowing the warm stratified air from the ceiling to the flooring. Natural ventilation is the ventilation of a structure with outside air without utilizing fans or other mechanical systems. It can be through operable windows, louvers, or trickle vents when areas are small and the architecture permits.

Natural ventilation schemes can use extremely little energy, however care needs to be required to make sure comfort. In warm or damp climates, maintaining thermal comfort solely by means of natural ventilation might not be possible. Air conditioning systems are used, either as backups or supplements. Air-side economizers also use outside air to condition spaces, but do so using fans, ducts, dampers, and control systems to introduce and distribute cool outdoor air when appropriate.