Adaptive Filter Control (0x0D,0x53)
| Description | Configures the basic setup for auto-adaptive filtering. See product manual for a detailed description of this feature. | |
| Notes | ||
| Parameter Name | Data Type | Description | 
| Field Length | u8 | 6 | 
| Descriptor | u8 | 0x53 | 
| Function Selector | u8 | This command supports the following MIP function selectors: Write Read Save Load Default 
                            [WRSLD]
                         | 
| Level | u8 | Auto-adaptive operating level: 0=Off, 1=Conservative, 2=Moderate (default), 3=Aggressive. | 
| Time Limit | u16 | Maximum duration of measurement rejection before entering recovery mode (ms) | 
| Response Data | Data Type | Description | 
| Response Length | u8 | 5 | 
| Response Descriptor | u8 | 0xD3 | 
| Level | u8 | Auto-adaptive operating level: 0=Off, 1=Conservative, 2=Moderate (default), 3=Aggressive. | 
| Time Limit | u16 | Maximum duration of measurement rejection before entering recovery mode (ms) |