Sensor Range (0x0C,0x52)
| Description | Changes the IMU sensor gain. | |||||||||||||||||||
| Notes | This allows you to optimize the range to get the best accuracy and performance while minimizing over-range events. Use the 3DM Get Calibrated Sensor Ranges (0x0C,0x53) command to determine the appropriate setting value for your application. Using values other than those specified may result in a NACK or inaccurate measurement data. | |||||||||||||||||||
| Parameter Name | Data Type | Description | ||||||||||||||||||
| Field Length | u8 | 5 | ||||||||||||||||||
| Descriptor | u8 | 0x52 | ||||||||||||||||||
| Function Selector | u8 | This command supports the following MIP function selectors: Write Read Save Load Default 
                            [WRSLD]
                         | ||||||||||||||||||
| Sensor 
                            [WRSLD]
                         | u8 enum | Which type of sensor will get the new range value. 
 | ||||||||||||||||||
| Setting 
                            [W]
                         | u8 | Use the 3DM Get Calibrated Sensor Ranges (0x0C,0x53) command to determine this value. | ||||||||||||||||||
| Response Data | Data Type | Description | ||||||||||||||||||
| Response Length | u8 | 4 | ||||||||||||||||||
| Response Descriptor | u8 | 0xD2 | ||||||||||||||||||
| Sensor | u8 enum | Which type of sensor will get the new range value. 
 | ||||||||||||||||||
| Setting | u8 | Use the 3DM Get Calibrated Sensor Ranges (0x0C,0x53) command to determine this value. | ||||||||||||||||||