Power Supply (EqualLogic) Check
The Power Supply (EqualLogic) Check monitors the overall condition of the power supply for a Dell EqualLogic SAN.
Basic Check information
| Check Type | SNMP |
| Instances on a Device | 5 |
| Supported Systems/Applications | Dell EqualLogic SANs that support the EQLMEMBER-MIB MIB |
| Device Class | Server - Generic and Server - Windows |
Troubleshooting
| Issue | Corrective Action |
|---|---|
| Failed | Please check that the correct SNMP community string is configured in Network Discovery for the device |
| 201 Exception OID_TYPE_NOSUCHOBJECT | Missing OID object on the device for specific metric |
OID/Calculation
| Metric Name | OID/Calculation | Description |
|---|---|---|
| Power Supply Status | 1.3.6.1.4.1.12740.2.1.8.1.3 |
The status of the power supply mapped as:
|
| Power Supply Fan Status | 1.3.6.1.4.1.12740.2.1.8.1.4 |
If the Power Supply Status is on and operating, this field indicates that the operational state of the fan. Fan states are mapped as:
|
| Power Supply Firmware Version | 1.3.6.1.4.1.12740.2.1.8.1.5 | Specifies the firmware version of the power supply. |