Qualcomm Technologies, Inc. CPR4 Regulator - MMSS LDO Specific Bindings

MMSS LDO CPR4 controllers each support one CPR thread that monitors the voltage
of the graphics processor (MMSS) supply regulator.  The CPR open-loop voltages
are stored in hardware fuses for MMSS CPR4 controllers.  However, the CPR target
quotients must be defined in device tree.

This document describes the MMSS LDO specific CPR4 bindings.

=======================
Required Node Structure
=======================

CPR3 regulators must be described in three levels of devices nodes.  The first
level describes the CPR3 controller.  The second level describes exacly one
hardware thread managed by the controller.  The third level describes one or
more logical regulators handled by the CPR thread.

All platform independent cpr3-regulator binding guidelines defined in
cpr3-regulator.txt also apply to cpr4-mmss-ldo-regulator devices.

====================================
First Level Nodes - CPR3 Controllers
====================================

MMSS LDO specific properties:
- compatible
	Usage:      required
	Value type: <string>
	Definition: should be the following:
		    "qcom,cpr4-sdm660-mmss-ldo-regulator" for SDM660,
		    "qcom,cpr4-sdm630-mmss-ldo-regulator" for SDM630.

- clocks
	Usage:      required
	Value type: <prop-encoded-array>
	Definition: Array of clock tuples in which each tuple consists of a
		    phandle to a clock device and a clock ID number.  The
		    following clocks must be specified: MMSS RBCPR and MMSS
		    RBCPR AHB.

- clock-names
	Usage:      required
	Value type: <stringlist>
	Definition: Clock names.  This list must match up 1-to-1 with the clocks
		    specified in the 'clocks' property. "core_clk", and "bus_clk"
		    must be specified.

- qcom,cpr-step-quot-fixed
	Usage:      Optional
	Value type: <u32>
	Definition: Fixed step quotient value used by controller for applying
		    the SDELTA margin adjustments on the programmed target
		    quotient values. The step quotient is the number of
		    additional ring oscillator ticks observed for each
		    qcom,voltage-step increase in vdd-supply output voltage.
		    Supported values: 0 - 63.

=================================================
Second Level Nodes - CPR Threads for a Controller
=================================================

MMSS specific properties:
N/A

===============================================
Third Level Nodes - CPR Regulators for a Thread
===============================================

MMSS specific properties:
- qcom,cpr-fuse-corners
	Usage:      required
	Value type: <u32>
	Definition: Specifies the number of fuse corners. This value must be 6
		    for sdm660/sdm630 GFX LDO. These fuse corners are: MinSVS,
		    LowSVS, SVS, SVSP, NOM and NOMP. The open-loop voltage fuses
		    are allocated for LowSVS, SVS, NOM and NOMP corners. The
		    open-loop voltages for MinSVS and SVSP are derived by
		    applying fixed offset from LowSVS and NOM open-loop voltages
		    respectively. The closed-loop offset voltage fuses are
		    allocated for LowSVS, SVS, NOM and NOMP corners. The MinSVS
		    and SVSP corners use the closed-loop offset voltage fuses of
		    LowSVS and NOM corners respectively.

- qcom,cpr-fuse-combos
	Usage:      required
	Value type: <u32>
	Definition: Specifies the number of fuse combinations being supported by
		    the device.  This value is utilized by several other
		    properties.  Supported values are 1 up to the maximum
		    possible for a given regulator type.  For MMSS the maximum
		    supported value is 8.  These combos correspond to CPR
		    revision fuse values from 0 to 7 in order.

- qcom,mem-acc-voltage
	Usage:      required if mem-acc-supply is specified for the CPR3 controller
		    containing this CPR3 regulator
	Value type: <prop-encoded-array>
	Definition: A list of integer tuples which each define the mem-acc-supply
		    corner for each voltage corner in order from lowest to highest.

		    The list must contain qcom,cpr-fuse-combos number of tuples
		    in which case the tuples are matched to fuse combinations
		    1-to-1 or qcom,cpr-speed-bins number of tuples in which case
		    the tuples are matched to speed bins 1-to-1 or exactly 1
		    tuple which is used regardless of the fuse combination and
		    speed bin found on a given chip.

		    Each tuple must be of the length defined in the
		    corresponding element of the qcom,cpr-corners property or
		    the qcom,cpr-speed-bins property.  A single tuple may only
		    be specified if all of the corner counts in qcom,cpr-corners
		    are the same.

- qcom,cpr-target-quotients
	Usage:      required
	Value type: <prop-encoded-array>
	Definition: A grouping of integer tuple lists.  Each tuple defines the
		    CPR target quotient for each ring oscillator (RO) for a
		    given corner.  Since CPR3 supports exactly 16 ROs, each
		    tuple must contain 16 elements corresponding to RO0 through
		    RO15 in order.  If a given RO is unused for a corner, then
		    its target quotient should be specified as 0.

		    Each tuple list in the grouping must meet the same size
		    requirements as those specified for qcom,mem-acc-voltage
		    above. The tuples in a given list are ordered from the
		    lowest corner to the highest corner.

- qcom,cpr-ro-scaling-factor
	Usage:      required if qcom,cpr-closed-loop-voltage-adjustment is
		    specified
	Value type: <prop-encoded-array>
	Definition: The common definition of this property in cpr3-regulator.txt
		    is accurate for MMSS CPR3 controllers except for this
		    modification:

		    Each tuple list must contain the number of tuples defined in
		    the corresponding element of the qcom,cpr-corners property
		    or the qcom,cpr-speed-bins property as opposed to the value
		    of the qcom,cpr-fuse-corners property.

- qcom,cpr-fused-closed-loop-voltage-adjustment-map
	Usage:      optional
	Value type: <prop-encoded-array>
	Definition: A list of integer tuples which each define the CPR fused
		    corner closed-loop offset adjustment fuse to utilize for
		    each voltage corner in order from lowest to highest.

		    The list must contain qcom,cpr-fuse-combos number of tuples
		    in which case the tuples are matched to fuse combinations
		    1-to-1 or qcom,cpr-speed-bins number of tuples in which case
		    the tuples are matched to speed bins 1-to-1 or exactly 1
		    tuple which is used regardless of the fuse combination and
		    speed bin found on a given chip.

		    Each tuple must be of the length defined in the
		    corresponding element of the qcom,cpr-corners property or
		    the qcom,cpr-speed-bins property.  A single tuple may only
		    be specified if all of the corner counts in qcom,cpr-corners
		    are the same.

		    Each tuple element must be either 0 or in the range 1 to
		    qcom,cpr-fuse-corners.  A value of 0 signifies that no fuse
		    based adjustment should be applied to the fuse corner.
		    Values 1 to qcom,cpr-fuse-corners denote the specific fuse
		    corner that should be used by a given voltage corner.

- qcom,cpr-corner-allow-ldo-mode
	Usage:      optional
	Value type: <prop-encoded-array>
	Definition: A list of integer tuples which each define the LDO mode
		    allowed state for each voltage corner in order from lowest
		    to highest. Each element in the tuple should be either
		    0 (LDO mode not allowed) or 1 (LDO mode allowed).

		    The list must contain qcom,cpr-fuse-combos number of tuples
		    in which case the tuples are matched to fuse combinations
		    1-to-1 or qcom,cpr-speed-bins number of tuples in which case
		    the tuples are matched to speed bins 1-to-1 or exactly 1
		    tuple which is used regardless of the fuse combination and
		    speed bin found on a given chip.

		    Each tuple must be of the length defined in the
		    corresponding element of the qcom,cpr-corners property or
		    the qcom,cpr-speed-bin-corners property.  A single tuple may
		    only be specified if all of the corner counts in
		    qcom,cpr-corners are the same.

- qcom,cpr-corner-allow-closed-loop
	Usage:      optional
	Value type: <prop-encoded-array>
	Definition: A list of integer tuples which each define the CPR
		    closed-loop operation allowed state for each voltage corner
		    in order from lowest to highest. Each element in the tuple
		    should be either 0 (CPR closed-loop operation not allowed)
		    or 1 (CPR closed-loop operation allowed).

		    The list must contain qcom,cpr-fuse-combos number of tuples
		    in which case the tuples are matched to fuse combinations
		    1-to-1 or qcom,cpr-speed-bins number of tuples in which case
		    the tuples are matched to speed bins 1-to-1 or exactly 1
		    tuple which is used regardless of the fuse combination and
		    speed bin found on a given chip.

		    Each tuple must be of the length defined in the
		    corresponding element of the qcom,cpr-corners property or
		    the qcom,cpr-speed-bin-corners property.  A single tuple may
		    only be specified if all of the corner counts in
		    qcom,cpr-corners are the same.

Note that the qcom,cpr-closed-loop-voltage-fuse-adjustment property is not
meaningful for MMSS LDO CPR3 regulator nodes since target quotients are not
defined in fuses.

=======
Example
=======

gfx_cpr: cpr4-ctrl@05061000 {
	compatible = "qcom,cpr4-sdm660-mmss-ldo-regulator";
	reg = <0x05061000 0x4000>, <0x00784000 0x1000>;
	reg-names = "cpr_ctrl", "fuse_base";
	interrupts = <GIC_SPI 285 IRQ_TYPE_EDGE_RISING>;
	interrupt-names = "cpr";
	qcom,cpr-ctrl-name = "gfx";

	qcom,cpr-sensor-time = <1000>;
	qcom,cpr-loop-time = <5000000>;
	qcom,cpr-idle-cycles = <15>;
	qcom,cpr-step-quot-init-min = <8>;
	qcom,cpr-step-quot-init-max = <12>;
	qcom,cpr-count-mode = <0>;		/* All at once */

	vdd-supply = <&gfx_stub_vreg>;
	mem-acc-supply = <&gfx_mem_acc_vreg>;
	system-supply = <&pm660l_s3_level>; /* vdd_cx */
	qcom,voltage-step = <5000>;
	vdd-thread0-ldo-supply = <&gfx_ldo_vreg>;

	qcom,cpr-enable;

	thread@0 {
		qcom,cpr-thread-id = <0>;
		qcom,cpr-consecutive-up = <0>;
		qcom,cpr-consecutive-down = <2>;
		qcom,cpr-up-threshold = <0>;
		qcom,cpr-down-threshold = <2>;

		gfx_vreg_corner: regulator {
			regulator-name = "gfx_corner";
			regulator-min-microvolt = <1>;
			regulator-max-microvolt = <7>;

			qcom,cpr-fuse-corners = <6>;
			qcom,cpr-fuse-combos = <8>;
			qcom,cpr-corners = <7>;

			qcom,cpr-corner-fmax-map = <1 2 3 4 5 6>;

			qcom,cpr-voltage-ceiling =
				<584000  644000  724000  788000
				 868000  924000 1068000>;
			qcom,cpr-voltage-floor =
				<504000  504000  596000  652000
				 712000  744000 1068000>;

			qcom,mem-acc-voltage = <1 1 1 2 2 2 2>;
			qcom,system-voltage =
				<RPM_SMD_REGULATOR_LEVEL_MIN_SVS>,
				<RPM_SMD_REGULATOR_LEVEL_LOW_SVS>,
				<RPM_SMD_REGULATOR_LEVEL_SVS>,
				<RPM_SMD_REGULATOR_LEVEL_SVS_PLUS>,
				<RPM_SMD_REGULATOR_LEVEL_NOM>,
				<RPM_SMD_REGULATOR_LEVEL_NOM_PLUS>,
				<RPM_SMD_REGULATOR_LEVEL_TURBO>;

			qcom,corner-frequencies =
				<160000000 266000000 370000000
				 465000000 588000000 647000000
				 800000000>;

			qcom,cpr-target-quotients =
				<0    0    0    0     0    0  185  179
				291  299  304  319    0    0    0    0>,
				<0    0    0    0     0    0  287  273
				425  426  443  453    0    0    0    0>,
				<0    0    0    0     0    0  414  392
				584  576  608  612    0    0    0    0>,
				<0    0    0    0     0    0  459  431
				684  644  692  679    0    0    0    0>,
				<0    0    0    0     0    0  577  543
				798  768  823  810    0    0    0    0>,
				<0    0    0    0     0    0  669  629
				886  864  924  911    0    0    0    0>,
				<0    0    0    0     0    0    0    0
				 0    0    0    0     0    0    0    0>;

			qcom,cpr-ro-scaling-factor =
				<  0    0    0    0   0    0 2035 1917
				1959 2131 2246 2253   0    0    0    0>,
				<  0    0    0    0   0    0 2035 1917
				1959 2131 2246 2253   0    0    0    0>,
				<  0    0    0    0   0    0 2035 1917
				1959 2131 2246 2253   0    0    0    0>,
				<  0    0    0    0   0    0 2035 1917
				1959 2131 2246 2253   0    0    0    0>,
				<  0    0    0    0   0    0 2035 1917
				1959 2131 2246 2253   0    0    0    0>,
				<  0    0    0    0   0    0 2035 1917
				1959 2131 2246 2253   0    0    0    0>,
				<  0    0    0    0   0    0    0    0
				   0    0    0    0   0    0    0    0>;

			qcom,cpr-scaled-open-loop-voltage-as-ceiling;
			qcom,cpr-corner-ldo-mode-allowed =
				<1 1 1 1 1 1 0>;
			qcom,cpr-corner-use-closed-loop =
				<1 1 1 1 1 1 0>;
		};
	};
};
