The fan unit has 4 wires - 1 green wire that is capped, 1 blue wire labelled "for light", 1 black wire, and 1 white wire. Or do I need to replace the new remote receiver unit with a different one that has the third "common out" wire? According to the installation instructions for a Hunter Universal Fan & Light Remote Control (Model 27185), the device should be wired as follows. Doing my best to interpret your question: First, call the unit you wire in with the fan the "receiver," since it receives signals from the remote transmitter to control the fan (and usually a light). Connect the green to the ceiling fan's green wires and the bare copper ground wire in the ceiling box.
Not the answer you're looking for?Browse other questions tagged wiring ceiling-fan installation or ask your own question. Is it wrong to connect the red ceiling wire to the blue wire on my receiver for the remote and the blue wire from the fan? Are Hilbert-Schmidt operators on separable Hilbert spaces "Hilbert Schmidt" on the space of Hilbert Schmidt Operators?
Why did Arab spring and Iranian green revolution fail, but the European revolutions didn't?
The email address entered is already associated to an account.Login to post Please use English characters only. The first step (as always) is to determine what circuit breaker feeds power to the circuit we are working on, and shut off that breaker.  For a quick review of safety considerations when working around electricity, CLICK HERE. Now that the breaker is off, and the electrical panel is locked (if so equipped) so nobody can accidentally turn the breaker back on while you are working on the circuit you can safely begin working. If you don’t have provisions for locking off the access to the panel, put a piece of electrical tape over the breaker handle holding it in the off position, and post a note warning others to leave the breaker off. The next step is to remove the canopy of the fan to check on the existing wiring, and plan for the installation of the remote control receiver unit. The white wire from the supply cable will connect to the line in neutral, and the black wire will connect to the live in, or power in wire from the receiver. With all the connections made, we need to tuck the wires back into the box and install the remote receiver in the space available in the mounting bracket. When the remote receiver is installed and the canopy and trim ring are back in place, we can now make our changes in the multi-gang switch box.


With the switches back in place, and the faceplate installed, it’s time to check our installation. Changing a ceiling fan to remote control is an excellent solution for many applications, but especially in a bedroom where the switch is by the entrance door. If you aren’t comfortable and confident in safely completing a project like this on your own, use the box on the left of the page to find a reliable trusted licensed electrician in your local area.
This entry was posted in How-To-Videos, Indoor Wiring and tagged ceiling fan, ceiling fan conversion, ceiling fan remote control, fan, remote control. Via email, text message, or notification as you wait on our site.Ask follow up questions if you need to.
I have the typical Hunter ceiling fan issue where the lights blink because of a faulty wattage limiter. That is actually just a paper tag on the black wire 'Connect light kit black wire here' there is also a similar tag on the white wire.
The block on the fan assembly only has 6 wires coming out of it and going into the middle where the center of the motor would be. I'm going to pull the light's wall switch out of the wall and use a wire nut to tie the two wire that go into it together. Yes,Very common.They pull a 3 wire cable to the ceiling so the light and fan are separated and can work independently with their own switches. Well, without the wall switch for the light when the circuit breaker goes back on there is about a 15 second lag and both of the lights start to strobe again. I put the wall switch back in the circuit and flipped the circuit breaker and the lights began to strobe again.My previous statement that it took about 15 second lag to begin to strobe could have been misleading.
If you can find the black and the red and the white coming out of the ceiling then you may have two switches on the wall for that fan, red for black fan wire, black with white stripe for the to black out of the ceiling , white all together.
With this particular fan, a trim ring conceals the four mounting screws that hold the canopy cover in place. There is a 3-wire cable in the outlet box that provides a common neutral (white) wire, and the fan’s light kit is connected to the red, and the fan is connected to the black conductor.
This can be a difficult job to make everything fit, but it’s important that everything fits in nicely and that no wires are pinched or jammed in too tightly so to avoid any damage to the conductors, potentially causing a short circuit condition. Remove the faceplate and the device screws and determine that the switch that controlled the light has a red wire on one terminal, and the switch that controlled the fan has a black wire on one side of it. You can keep the remote on the bedside table, and have access to the light and the fan if needed in the middle of the night, without getting out of bed!


We only need one of these switched hot wires to act as the master power for the receiver unit. Both switches will have a black hot wire from the same hot splice connected to each switch.
The fan speed and direction will have to be set to the desired position using the pull-chain and reverse switch, and the light kit pull-chain will have to be on as well in order for the remote to work. Just connect the 2 wires together eliminating the switch for a test.Or you can test the switches with a tester.
You only need to completely remove one of the screws on each side, and just loosen the other two that are through the key-hole, or L-slots in the canopy cover to allow it to drop out of the way, exposing the mounting bracket and the fan wiring. I will move the switch we are still using to the middle position, keep the switch for the room’s receptacles in the first position, and then use a blank filler plate to fill the position of the switch we removed.
That is the reason why many people who purchased this kind of fan give either their approval or disapproval. Ceiling fans are not just meant for providing cool breeze but for decorative reasons as well.
In opting for a fan design, you need to put into consideration its color idea by making sure that it can match and also blend well with the room in which it will be installed.Same is used in opting for the style as a simple fan is well suited to modern houses whereas gold and wooden colors with matching elaborate style can best fit in classic houses.
Alternately, you can select a fan having a contrasting color on every surface of the blade. However, a black ceiling fan has blades which are not that fine in giving lighting to a room as its dark color will reduce the light which gets in contact with the floor. Moreover, the same happens with the lighting above the blades; this light will not be reflected yet absorbed that considerably decreases the amount of lighting around the area. It will make the blades hot which will raise the possibility of fading and possible damage of the blade so requiring future substitute.The benefit of a black ceiling fan however is its simple maintenance. You can bring back its charm and beauty simply by painting the blades making use of a black paint. The task does not need too much effort and you can search for a black paint easily which has the same shade with the fan blades.




Online rpg free multiplayer
Havells pedestal fan online shopping india electronics
Hunter ceiling fan replacement blades black xs
Usha rechargeable table fan price in chennai now
11.02.2015 admin



Comments to «Hunter ceiling fan black and white wire youtube»

  1. Playgirl writes:
    Offers a huge choice of designs ranging from sleek and the lights (flourescents) are totally.
  2. LEZBIYANKA writes:
    Nickel finish and three kits will expense.